Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
Re: COMREC Error 72
> Jan 20 06:36:52.05: [ 661]: RECV: 10039 bytes of data, 457 total lines
This is very short. I wonder if you have the serial port set at 9600?
> Jan 20 06:36:52.05: [ 661]: --> [21:+FPTS:2,456,456,456,0]
> Jan 20 06:36:53.31: [ 661]: --> [6:+FET:2]
> Jan 20 06:36:53.31: [ 661]: RECV recv EOP (no more pages or documents)
> Jan 20 06:36:53.31: [ 661]: --> [2:OK]
> Jan 20 06:36:53.31: [ 661]: RECV send RTN (retrain negative)
This is the real error. If Hylafax sends RTN, it almost certainly means
that there are excessive numbers of coding errors in the received data,
which would be the case for a receive overrun.