On 2004.07.29 06:39 Steve Melo wrote:
>From the older faxrcvd script:
MIMENCODE=base64-encode
ENCODING=base64

>From the newer script:
ENCODING=base64
MIMENCODE=mimencode

Well, that's what the problem was. Looks like you previously set MIMENCODE to something that HylaFAX didn't know existed in the new release. You'll need to modify the new faxrcvd similarly if you want to use it.


Currently faxsetup only knows about mimencode and uuencode. So it has no ability to utilize base64-encode. Is that a program that came with your distribution?

Lee.