[hylafax-users] Incompatible TIFF Library error at configure time



System: Sparc Solaris 2.8; HylaFAX 4.1.8

We have been successfully running HylaFAX for several years and been through several installations, but never had the following problem.

While running the ./configure command, we get the following error:

... checking TIFF library version
ld.so.1: ./a.out: fatal: relocation error: file ./a.out: symbol TIFFGetVersion: referenced symbol not found
Found tiffio.h version 0
Found libtiff version


Incompatible TIFF Library.

I have tried tiff version 3.4, 3.5 & 3.6 and always get the same error. I think they installed in the same places the HylaFAX config.site files points to:

#LIBTIFF="-L/usr/local/lib -ltiff"      # linkage convention for
#TIFFINC="/usr/local/include"           # place to find tiffio.h
#TIFFBIN="/usr/local/bin"               # where TIFF tools live

In the tiffio.h file, the version definition is as follows:
#define TIFFLIB_VERSION 19960307        /* March 7, 1996 */

We really need to get this system back up, so you help is greatly appreciated!

- Ron