Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
[hylafax-users] REMOTE HANGUP: No response to EOP repeated 3 times (code 54)
Hi all, I got this error msg for my AzTech 56K external modem, anybody got
clue to resolve it?
Aug 10 01:37:48.19: [ 2683]: SENT 28148 bytes of data
Aug 10 01:37:48.19: [ 2683]: <-- data [2]
Aug 10 01:37:48.37: [ 2683]: SEND end page
Aug 10 01:37:49.22: [ 2683]: --> [2:OK]
Aug 10 01:37:49.22: [ 2683]: SEND send EOP (no more pages or documents)
Aug 10 01:37:49.22: [ 2683]: <-- [9:AT+FET=2\r]
Aug 10 01:37:59.56: [ 2683]: --> [9:+FHNG: 54]
Aug 10 01:37:59.56: [ 2683]: REMOTE HANGUP: No response to EOP repeated 3
times (code 54)
Aug 10 01:37:59.56: [ 2683]: <-- [5:ATH0\r]
Aug 10 01:38:00.26: [ 2683]: --> [2:OK]
Aug 10 01:38:00.26: [ 2683]: SESSION END
--- modem config for config.ttyS0
...
...
...
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use class 2 interface
ModemRate: 19200
ModemFlowControl: xonxoff # default
ModemWaitForConnect: yes # wait for CONNECT on answer
#
#ModemResetCmds: AT&F2 # what you want for a Supra
ModemNoFlowCmd: AT&K # disable flow control cmd
ModemHardFlowCmd: AT&K3 # hardware flow control cmd
ModemSoftFlowCmd: AT&K4 # software flow control cmd
ModemSetupDTRCmd: AT&D3 # DTR off causes modem to reset
ModemSetupDCDCmd: AT&C1 # DCD follows carrier
ModemSetupAACmd: AT+FCLASS=0;+FAA=1 # enable in class 0
#
ModemSendFillOrder: LSB2MSB # as expected
ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
Class2RecvDataTrigger: "\022" # a la 2388-B