Re: [hylafax-users] [SOLVED] RE: factors in bad scan lines



>> in the config file.  I never would have caught that on my own.  So, I guess
>> that my question is, how are you supposed to know the proper settings for:
>> 
>> ModemSendFillOrder
>> ModemRecvFillOrder
>> ModemFrameFillOrder
>> 
>> as I've never seen them listed in any manual?
>
>What about T.30? :-)

Okay, you got me.  :)  I haven't read T.30.

>The correct settings are:
>
>Class1:
>ModemSendFillOrder      LSB2MSB
>ModemRecvFillOrder      LSB2MSB
>ModemFrameFillOrder     LSB2MSB
>
>Class2:
>ModemSendFillOrder      LSB2MSB
>ModemRecvFillOrder      MSB2LSB (infamous Rockwell bug)
>ModemFrameFillOrder     Not applicable
>
>Initially Rockwell was introduced this bug in its modem's data pump (Class2
>also assumed LSB2MSB), which most software and hardware makers had to
>follow. I know the only exception -- non-Rockwell Multitech modems, that
>implements the original Class2 specs and use LSB2MSB for ModemRecvFillOrder.
>
>Class2.0:
>ModemSendFillOrder      LSB2MSB
>ModemRecvFillOrder      LSB2MSB
>ModemFrameFillOrder     Not applicable

Thank you!

So, should a "default" config setting for Class 2 be 'ModemRecvFillOrder:
MSB2LSB' ?
This "default" wouldn't work for Multitech, but for everything else?

Lee.



____________________ HylaFAX(tm) Users Mailing List _______________________
 To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null



Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services