Hylafax Mailing List Archives

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: Trouble receiving Faxes with Elsa Microlink 56k Basic Modem



Karlheinz Blank wrote:
> 
> Hi,
> 
HI,

try the attached config-file for elsa modem
 HIH
/Matthias

> in near future I'll get trouble - cause I'm sitting every night in front of my computer trying to get that following running :-(
> 
> - Suse 6.4
> - Hylafax 4.1 beta 2
> - Elsa Microlink 56k basic
> 
> I'm running faxaddmodem with defining the modem either as Class 1, 2 or 2.0 type.
> But if I receive a fax, the modem connects - exchanges the FAX-Device-IDs from and to the sending fax-machine - and nothing happens til the sending fax hangs up with an error.
> 
> I increased the logging level, I searched through the hylafax archive, I've been changing the modem - nothing helped.
> I was searching the Elsa Homepage but didn't find a config.modem file...
> 
> Thanks for any hints.
> 
> I've tested the following configs:
> 
> CLASS 1:
> -----------
> May 24 23:22:38.36: [  462]: SESSION BEGIN 00000024 491111111
> May 24 23:22:47.28: [  462]: ANSWER: FAX CONNECTION
> May 24 23:22:47.28: [  462]: MODEM input buffering enabled
> May 24 23:22:47.28: [  462]: RECV FAX: begin
> May 24 23:22:51.15: [  462]: REMOTE TSI "+491111111"
> May 24 23:22:51.15: [  462]: REMOTE wants 9600 bit/s
> May 24 23:22:51.15: [  462]: REMOTE wants page width 1728 pixels in 215 mm
> May 24 23:22:51.15: [  462]: REMOTE wants unlimited page length
> May 24 23:22:51.15: [  462]: REMOTE wants 3.85 line/mm
> May 24 23:22:51.15: [  462]: REMOTE wants 1-D MR
> May 24 23:22:53.76: [  462]: RECV: begin page
> May 24 23:22:53.76: [  462]: RECV: send trigger 021
> 
> **** Process hangs after that - no more entries in log...
> 
> *** SNIP **********
> 
> ModemType:              Class1          # use this to supply a hint
> ModemRate:              38400           # rate for DCE-DTE communication
> ModemFlowControl:       rtscts          # XON/XOFF flow control assumed
> #  ******** tested with XONXOFF as well.
> GettyArgs:              "-h %l dx_%s"   # modem must auto-detect fax/data
> Class1Cmd:              AT+FCLASS=1     # command to enter class 1
> Class1TCFResponseDelay: 75              # 75ms delay between recv TCF & response
> Class1SendPPMDelay:     75              # 75ms delay before sending PPM
> Class1SendTCFDelay:     75              # 75ms delay between sending DCS & TCF
> Class1TrainingRecovery: 1500            # 1.5sec delay after training failure
> Class1RecvAbortOK:      200             # wait 200ms for abort response
> Class1FrameOverhead:    4               # 4 byte overhead in recvd HDLC frames
> Class1RecvIdentTimer:   40000           # 35+5secs waiting for ident frames
> Class1TCFMaxNonZero:    10              # max 10% of data may be non-zero
> Class1TCFMinRun:        1000            # min run is 2/3rds of TCF duration
> 
> *********+ SNIP
> 
> Class 2.0
> 
> May 24 23:30:11.12: [  562]: SESSION BEGIN 00000025 49111111
> May 24 23:30:11.12: [  562]: <-- [4:ATA\r]
> May 24 23:30:17.22: [  562]: --> [74:+FHT: FF 03 40 20 20 20 48 62 6D 47 20 6B 63 75 72 44 20 6B 69 66 61 72 47]
> May 24 23:30:17.22: [  562]: --> [26:+FHT: FF 13 80 00 6E F8 00]
> May 24 23:30:19.87: [  562]: --> [5:+FCON]
> May 24 23:30:21.38: [  562]: --> [74:+FHR: FF 03 43 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 78 61 46]
> May 24 23:30:21.60: [  562]: --> [23:+FHR: FF 13 83 00 62 70]
> May 24 23:30:25.03: [  562]: --> [5:+FCFR]
> May 24 23:30:25.03: [  562]: --> [28:+FTSI:"Fax                 "]
> May 24 23:30:25.04: [  562]: --> [21:+FDCS:1,5,0,0,0,0,0,0]
> May 24 23:30:25.04: [  562]: --> [2:OK]
> May 24 23:30:25.04: [  562]: <-- [7:AT+FDR\r]
> May 24 23:30:25.19: [  562]: --> [14:+FHT: FF 13 84]
> May 24 23:30:27.08: [  562]: --> [7:CONNECT]
> May 24 23:30:27.08: [  562]: <-- data [1]
> 
> *** Nothing happens after that point.
> 
> _______________________________________________________________________
> 1.000.000 DM gewinnen - kostenlos tippen - http://millionenklick.web.de
> IhrName@web.de, 8MB Speicher, Verschluesselung - http://freemail.web.de

-- 
HAGOS eG                 phone: +49 711 7880592
Matthias Reich             fax: +49 711 7880599
Industriestr. 62           web: http://www.hagos.de
D-70565 Stuttgart         mail: rei@hagos.de
Germany
----------------------------------------------------------------------------
Be careful your mail is read by the NSA too !!
# $Id: class2,v 1.23 1996/06/24 02:58:32 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
# 
# Permission to use, copy, modify, distribute, and sell this software and 
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
# 
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
# 
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
# OF THIS SOFTWARE.
#

#
# Generic Class 2 modem configuration.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode:		49
AreaCode:		711
FAXNumber:		+49.711.7880549
LongDistancePrefix:	0
InternationalPrefix:	00
DialStringRules:	etc/dialrules
ServerTracing:		0
SessionTracing:		0
RecvFileMode:		0600
LogFileMode:		0600
DeviceMode:		0600
RingsBeforeAnswer:	1
SpeakerVolume:		off
GettyArgs:		"-h %l dx_%s"
LocalIdentifier:	"HAGOS eG Stuttgart"
TagLineFont:		etc/lutRS18.pcf
TagLineFormat:		"   Von %%l|%c|Seite %%p von %%t"
QualifyTSI:		etc/tsi
MaxRecvPages:		25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:		Class2		# use this to supply a hint
ModemRate:		38400
ModemFlowControl:	rtscts
ModemSetupDTRCmd:	AT&D2		# setup so DTR drop resets modem
ModemSetupDCDCmd:	AT&C1		# setup so DCD reflects carrier (or not)
#
# We normally append the "@" symbol to the dial string so that
# the modem will wait 5 seconds before attempting to connect
# and return result codes that distinguish between no carrier
# and no answer.  This makes it possible to avoid problems with
# repeatedly dialing a number that doesn't have a fax machine
# (kudos to Stuart Lynne for this trick.)
#
# NB: If you need to prefix phone numbers to get through a PBX,
#     put it in the ModemDialCmd; e.g. "DT9%s@".
#
ModemDialCmd:		ATDT0,%s
#
# Other possible configuration stuff.  The default strings are
# shown below.  Only those that are different from the defaults
# need to be included in the configuration file.
#
ModemResetCmds:		ATX3		# stuff to do when modem is reset
ModemAnswerCmd:		ATA		# use this to answer phone
ModemNoFlowCmd:		AT\Q0		# disable flow control cmd
ModemHardFlowCmd:	AT\Q3		# hardware flow control cmd
ModemSoftFlowCmd:	AT\Q1		# software flow control cmd
ModemNoAutoAnswerCmd:	ATS0=0		# disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
ModemSetVolumeCmd:	"ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
ModemEchoOffCmd:	ATE0		# disable command echo
ModemVerboseResultsCmd:	ATV1		# enable verbose command results
ModemResultCodesCmd:	ATQ0		# enable result codes
ModemOnHookCmd:		ATH
ModemSoftResetCmd:	ATZ		# do soft reset of modem
ModemWaitTimeCmd:	ATS7=60		# wait 60 seconds for carrier
ModemCommaPauseTimeCmd:	ATS8=2		# comma pause time is 2 seconds
ModemRecvFillOrder:	LSB2MSB		# bit order of received facsimile
ModemSendFillOrder:	LSB2MSB		# bit order modem expects for transmit
#
# Configuration parameters for Class 2 modems.
#
Class2Cmd:		AT+FCLASS=2	# command to enter class 2
Class2BORCmd:		AT+FBOR=0	# bit order for phase B/C/D (direct)
Class2RELCmd:		AT+FREL=1	# byte-align EOL codes on recv
Class2CQCmd:		""		# commands to enable copy quality proc.
Class2AbortCmd:		AT+FK		# abort session command
Class2CQQueryCmd:	AT+FCQ=?	# query for copy quality capabilities
Class2DCCQueryCmd:	AT+FDCC=?	# query for modem capabilities
Class2TBCCmd:		AT+FTBC=0	# setup stream mode
Class2CRCmd:		AT+FCR=1	# enable capability to receive
Class2PHCTOCmd:		AT+FPHCTO=30	# set phase C timeout parameter
Class2BUGCmd:		AT+FBUG=1	# enable HDLC frame tracing
Class2LIDCmd:		AT+FLID		# set local identifier command
Class2DCCCmd:		AT+FDCC		# set modem capabilities command
Class2DISCmd:		AT+FDIS		# set session parameters command
Class2DDISCmd:		""		# disable pre-dial DIS command hack
Class2CIGCmd:		AT+FCIG		# set polling identifier command
Class2PTSCmd:		AT+FPTS		# set post-page status command
Class2SPLCmd:		AT+FSPL		# set polling indicator command
#
# If Class2RecvDataTrigger is not set, then it is set to DC1
#
Class2RecvDataTrigger:	""		# character sent to modem to start recv
Class2XmitWaitForXON:	yes		# if true, wait for XON before send


Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services