Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
Re: COMREC error
> May 22 19:52:20.15: [ 515]: RECV: 17074 bytes of data, 1133 total lines
> May 22 19:52:20.15: [ 515]: --> [15:+FPTS:2,0,0,0,0]
It more or less has to have broken at this point. I don't have a good
control example, but I think the modem is reporting no good lines
received, even though Hylafax has detected a reasonable number.
> May 22 19:52:21.43: [ 515]: --> [6:+FET:2]
> May 22 19:52:21.43: [ 515]: RECV recv EOP (no more pages or documents)
> May 22 19:52:21.43: [ 515]: --> [2:OK]
> May 22 19:52:21.43: [ 515]: RECV send RTN (retrain negative)
Hylafax then initiates an RTN (not to be confused with the problem of
receiving one).
> May 22 19:52:21.43: [ 515]: <-- [7:AT+FDR\r]
> May 22 19:52:24.31: [ 515]: --> [8:+FHNG:72]
> May 22 19:52:24.31: [ 515]: REMOTE HANGUP: COMREC error (code 72)
But the remote side is not prepared to resend, possibly because it would
mean manually repositioning the document.