Hylafax Mailing List Archives

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: COMREC error



> May 22 19:52:20.15: [  515]: RECV: 17074 bytes of data, 1133 total lines
> May 22 19:52:20.15: [  515]: --> [15:+FPTS:2,0,0,0,0]

It more or less has to have broken at this point.  I don't have a good
control example, but I think the modem is reporting no good lines 
received, even though Hylafax has detected a reasonable number.

> May 22 19:52:21.43: [  515]: --> [6:+FET:2]
> May 22 19:52:21.43: [  515]: RECV recv EOP (no more pages or documents)
> May 22 19:52:21.43: [  515]: --> [2:OK]
> May 22 19:52:21.43: [  515]: RECV send RTN (retrain negative)

Hylafax then initiates an RTN (not to be confused with the problem of
receiving one).

> May 22 19:52:21.43: [  515]: <-- [7:AT+FDR\r]
> May 22 19:52:24.31: [  515]: --> [8:+FHNG:72]
> May 22 19:52:24.31: [  515]: REMOTE HANGUP: COMREC error (code 72)

But the remote side is not prepared to resend, possibly because it would
mean manually repositioning the document.



Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services