[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: MT3334ZDX Partial Success



On Thu, 4 May 2000, Kirk Bocek wrote:

> Well, I mostly got a MultiTech MT3334ZDX modem to work with a
> hylafax-4.1beta1-1rh6.i386 install. I added the following lines from the
> rockwell-k56.config patch to the config file generated by faxaddmodem:
> 
> ModemSendFillOrder:	LSB2MSB		# as expected
> ModemRecvFillOrder:	MSB2LSB		# opposite of what makes sense
> Class2RecvDataTrigger:	"\022"		# a la 2388-B
> 
> And it _seemed_ to work. However...
> 
If you are running in Class2 mode you might find these helpfull.

Class2XmitWaitForXON:   no
#
Class2APQueryCmd:       ""              # AT+FAP=? not supported on this modem
Class2NFLOCmd:          AT+FLO=0        # Class 2: no flow control
Class2SFLOCmd:          AT+FLO=1        # Class 2: software flow control
Class2HFLOCmd:          AT+FLO=2        # Class 2: hardware flow control

> Multi-page faxes have many errors in them.
> 
> Is there something else I could add to the config file or is this part of
> the transmission error patches I see posted?
> 
> Kirk Bocek
> 

-- 
Tim Rice				Multitalents	(707) 874-1130