Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
modem hangs up after 30s
- using Linux 2.2.5, Suse 6.1, Hylafax/faxgetty -
Hello,
my modem hangs up after 30 sec ringing. To enable
60 Seconds I wrote 60 sec to register S7
ATS7=3D60
But faxgetty seems to overwrite these settings. Further,
I state that the setting are always reset to 45 sec after
reboot of the modem or after ATZ. When I write
the setting to profile 0 with AT&W0 the setting
is reset, too.
Trying minicom all works fine. The modem is ringing
as long as I forced it with register S7. Where can I
configure faxgetty ?
Here is my config.ttyS0:
# $Id: exar,v 1.7 1996/06/24 02:58:34 sam Rel $
#
[.. cut, ekkard ..]
# sending and for receiving. XON/XOFF flow control is used on
# the tty port.
#
CountryCode: 49
AreaCode: 721
FAXNumber: +49.721.380648
LongDistancePrefix: 0
InternationalPrefix: 0049
DialStringRules: etc/dialrules
ServerTracing: 527
SessionTracing: 527
RecvFileMode: 0644
LogFileMode: 0600
DeviceMode: 0666
RingsBeforeAnswer: 1
SpeakerVolume: low
GettyArgs: "-r -b -s %s %l"
LocalIdentifier: "Umweltzentrum"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "From %%l|%c|Page %%p of %%t"
MaxRecvPages: 25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use class 2 interface
ModemRate: 19200 # fax send&recv is locked at 19.2
ModemFlowControl: xonxoff # default
#
ModemSoftFlowCmd: AT&S1\G0\Q4\X1 # software flow control
ModemSetupDTRCmd: AT&D2 # DTR off causes modem to reset
ModemSetupDCDCmd: AT&C1 # DCD follows carrier
ModemSetupAACmd: AT+FAA=3D1 # enable in current class
#
ModemSendFillOrder: LSB2MSB # as expected
ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
#
ModemDialCmd: ATDT%s@ # T for tone dialing, @ for silence
#
ModemWaitForConnect: yes # wait for CONNECT on answer
#Diese Zeile hier eingef=FCgt, war nicht vorhanden !!! ????? Ekkard
ModemWaitTimeCmd: ATS7=3D120 # wait 60 seconds for carrier
Class2RecvDataTrigger: "\022" # DC2
Class2DDISCmd: AT+FDIS # set parameter before dialing
thank you
Ekkard