Single page-fax goes but multipage-fax goes not



Hi

I've just setup hylafax 4.0pl1 with an zyxel 1496E

Receiving of faxes runs without any problems!

Sending of faxes runs only for single-page-faxes!! Multipages are not send
correctly!

Here is a error info:
Mar 17 01:33:24.40: [ 6445]: SESSION BEGIN 00000327 410326537085
Mar 17 01:33:24.40: [ 6445]: SEND FAX: JOB 11 DEST 6537085 COMMID 00000327
Mar 17 01:33:24.40: [ 6445]: DELAY 2600 ms
Mar 17 01:33:27.01: [ 6445]: <--
[44:AT&B1&N0&S0*F0S18=2S38.3=1S39=0E0V1Q0S0=0H0\r]
Mar 17 01:33:27.23: [ 6445]: --> [2:OK]
Mar 17 01:33:27.23: [ 6445]: <-- [21:ATS8=2S7=60&H3&D2&C1\r]
Mar 17 01:33:27.25: [ 6445]: --> [2:OK]
Mar 17 01:33:27.25: [ 6445]: <-- [14:AT+FCLASS=2.0\r]
Mar 17 01:33:27.38: [ 6445]: --> [2:OK]
Mar 17 01:33:27.38: [ 6445]: <-- [9:AT+FLO=2\r]
Mar 17 01:33:27.39: [ 6445]: --> [2:OK]
Mar 17 01:33:27.39: [ 6445]: <-- [9:AT+FPP=0\r]
Mar 17 01:33:27.40: [ 6445]: --> [2:OK]
Mar 17 01:33:27.40: [ 6445]: <-- [9:AT+FBO=0\r]
Mar 17 01:33:27.41: [ 6445]: --> [2:OK]
Mar 17 01:33:27.41: [ 6445]: <-- [10:AT+FCT=30\r]
Mar 17 01:33:27.42: [ 6445]: --> [2:OK]
Mar 17 01:33:27.42: [ 6445]: <-- [15:AT+FNR=1,1,1,1\r]
Mar 17 01:33:27.43: [ 6445]: --> [2:OK]
Mar 17 01:33:27.43: [ 6445]: <-- [9:AT+FIE=0\r]
Mar 17 01:33:27.44: [ 6445]: --> [2:OK]
Mar 17 01:33:27.44: [ 6445]: <-- [23:AT+FCC=1,5,2,2,1,0,0,0\r]
Mar 17 01:33:27.46: [ 6445]: --> [2:OK]
Mar 17 01:33:27.46: [ 6445]: <-- [5:ATM0\r]
Mar 17 01:33:27.47: [ 6445]: --> [2:OK]
Mar 17 01:33:27.49: [ 6445]: <-- [14:AT+FCLASS=2.0\r]
Mar 17 01:33:27.72: [ 6445]: --> [2:OK]
Mar 17 01:33:27.72: [ 6445]: <-- [9:AT+FLO=2\r]
Mar 17 01:33:27.83: [ 6445]: --> [2:OK]
Mar 17 01:33:27.83: [ 6445]: <-- [9:AT+FPP=0\r]
Mar 17 01:33:27.94: [ 6445]: --> [2:OK]
Mar 17 01:33:27.94: [ 6445]: <-- [9:AT+FBO=0\r]
Mar 17 01:33:28.05: [ 6445]: --> [2:OK]
Mar 17 01:33:28.05: [ 6445]: <-- [10:AT+FCT=30\r]
Mar 17 01:33:28.16: [ 6445]: --> [2:OK]
Mar 17 01:33:28.16: [ 6445]: <-- [15:AT+FNR=1,1,1,1\r]
Mar 17 01:33:28.27: [ 6445]: --> [2:OK]
Mar 17 01:33:28.27: [ 6445]: <-- [9:AT+FIE=0\r]
Mar 17 01:33:28.38: [ 6445]: --> [2:OK]
Mar 17 01:33:28.38: [ 6445]: <-- [23:AT+FCC=1,5,2,2,1,0,0,0\r]
Mar 17 01:33:28.50: [ 6445]: --> [2:OK]
Mar 17 01:33:28.50: [ 6445]: <-- [24:AT+FLI="Tecno Software"\r]
Mar 17 01:33:28.62: [ 6445]: --> [2:OK]
Mar 17 01:33:28.62: [ 6445]: DIAL 6537085
Mar 17 01:33:28.62: [ 6445]: <-- [12:ATDT6537085\r]
Mar 17 01:34:02.88: [ 6445]: --> [4:+FCO]
Mar 17 01:34:02.88: [ 6445]: --> [96:+FNF:00 00 09 00 09 00 30 30 30 30 FF
FF FF FF FF FF FF FF 41 32 65 37 08 5F FF FF FF FF FF FF  ]
Mar 17 01:34:02.88: [ 6445]: REMOTE NSF "00 00 09 00 09 00 30 30 30 30 FF FF
FF FF FF FF FF FF 41 32 65 37 08 5F FF FF FF FF FF FF"
Mar 17 01:34:03.00: [ 6445]: --> [26:+FCI:      +41 32 6537085 ]
Mar 17 01:34:03.00: [ 6445]: REMOTE CSI "+41 32 6537085"
Mar 17 01:34:03.00: [ 6445]: --> [20:+FIS:1,3,0,2,1,1,0,3]
Mar 17 01:34:03.00: [ 6445]: --> [2:OK]
Mar 17 01:34:03.00: [ 6445]: REMOTE best rate 9600 bit/s
Mar 17 01:34:03.00: [ 6445]: REMOTE max page width 1728 pixels in 215 mm
Mar 17 01:34:03.00: [ 6445]: REMOTE max unlimited page length
Mar 17 01:34:03.00: [ 6445]: REMOTE best vres 7.7 line/mm
Mar 17 01:34:03.00: [ 6445]: REMOTE best format 2-D MR
Mar 17 01:34:03.00: [ 6445]: REMOTE supports T.30 Annex A, ECM
Mar 17 01:34:03.00: [ 6445]: REMOTE best 10 ms/scanline
Mar 17 01:34:03.00: [ 6445]: USE 9600 bit/s
Mar 17 01:34:03.00: [ 6445]: USE 10 ms/scanline
Mar 17 01:34:03.00: [ 6445]: SEND file "docq/doc2.ps;70"
Mar 17 01:34:03.00: [ 6445]: USE page width 1728 pixels in 215 mm
Mar 17 01:34:03.00: [ 6445]: USE unlimited page length
Mar 17 01:34:03.00: [ 6445]: USE 3.85 line/mm
Mar 17 01:34:03.00: [ 6445]: USE 2-D MR
Mar 17 01:34:03.00: [ 6445]: <-- [23:AT+FIS=0,3,0,2,1,0,0,3\r]
Mar 17 01:34:03.12: [ 6445]: --> [2:OK]
Mar 17 01:34:03.12: [ 6445]: <-- [7:AT+FDT\r]
Mar 17 01:34:09.06: [ 6445]: --> [20:+FCS:0,3,0,2,1,0,0,3]
Mar 17 01:34:09.06: [ 6445]: --> [7:CONNECT]
Mar 17 01:34:09.06: [ 6445]: SEND begin page
Mar 17 01:34:09.06: [ 6445]: <-- data [1030]
Mar 17 01:34:09.06: [ 6445]: <-- data [1033]
Mar 17 01:34:09.06: [ 6445]: <-- data [1033]
Mar 17 01:34:09.51: [ 6445]: <-- data [1033]
Mar 17 01:34:09.51: [ 6445]: <-- data [1034]
Mar 17 01:34:10.04: [ 6445]: <-- data [1041]
Mar 17 01:34:10.04: [ 6445]: <-- data [24]
Mar 17 01:34:10.05: [ 6445]: SENT 6168 bytes of data
Mar 17 01:34:10.05: [ 6445]: SEND 2D RTC
Mar 17 01:34:10.05: [ 6445]: <-- data [10]
Mar 17 01:34:10.05: [ 6445]: SEND end page
Mar 17 01:34:10.05: [ 6445]: SEND send MPS (more pages, same document)
Mar 17 01:34:10.05: [ 6445]: <-- data [2]
Mar 17 01:34:25.37: [ 6445]: --> [5:ERROR]
Mar 17 01:34:25.37: [ 6445]: SEND recv RTN (retrain negative)
Mar 17 01:34:25.37: [ 6445]: <-- [7:AT+FDT\r]
Mar 17 01:34:31.31: [ 6445]: --> [20:+FCS:0,3,0,2,1,0,0,3]
Mar 17 01:34:31.31: [ 6445]: --> [7:CONNECT]
Mar 17 01:34:31.31: [ 6445]: SEND begin page
Mar 17 01:34:31.31: [ 6445]: <-- data [1030]
Mar 17 01:34:31.31: [ 6445]: <-- data [1033]
Mar 17 01:34:31.31: [ 6445]: <-- data [1033]
Mar 17 01:34:31.76: [ 6445]: <-- data [1033]
Mar 17 01:34:31.76: [ 6445]: <-- data [1034]
Mar 17 01:34:32.29: [ 6445]: <-- data [1041]
Mar 17 01:34:32.29: [ 6445]: <-- data [24]
Mar 17 01:34:32.29: [ 6445]: SENT 6168 bytes of data
Mar 17 01:34:32.29: [ 6445]: SEND 2D RTC
Mar 17 01:34:32.30: [ 6445]: <-- data [10]
Mar 17 01:34:32.30: [ 6445]: SEND end page
Mar 17 01:34:32.30: [ 6445]: SEND send MPS (more pages, same document)
Mar 17 01:34:32.30: [ 6445]: <-- data [2]
Mar 17 01:34:47.64: [ 6445]: --> [5:ERROR]
Mar 17 01:34:47.64: [ 6445]: SEND recv RTN (retrain negative)
Mar 17 01:34:47.64: [ 6445]: <-- [7:AT+FDT\r]
Mar 17 01:34:53.55: [ 6445]: --> [20:+FCS:0,3,0,2,1,0,0,3]
Mar 17 01:34:53.55: [ 6445]: --> [7:CONNECT]
Mar 17 01:34:53.55: [ 6445]: SEND begin page
Mar 17 01:34:53.55: [ 6445]: <-- data [1030]
Mar 17 01:34:53.55: [ 6445]: <-- data [1033]
Mar 17 01:34:53.55: [ 6445]: <-- data [1033]
Mar 17 01:34:54.00: [ 6445]: <-- data [1033]
Mar 17 01:34:54.00: [ 6445]: <-- data [1034]
Mar 17 01:34:54.53: [ 6445]: <-- data [1041]
Mar 17 01:34:54.53: [ 6445]: <-- data [24]
Mar 17 01:34:54.53: [ 6445]: SENT 6168 bytes of data
Mar 17 01:34:54.53: [ 6445]: SEND 2D RTC
Mar 17 01:34:54.54: [ 6445]: <-- data [10]
Mar 17 01:34:54.54: [ 6445]: SEND end page
Mar 17 01:34:54.54: [ 6445]: SEND send MPS (more pages, same document)
Mar 17 01:34:54.54: [ 6445]: <-- data [2]
Mar 17 01:35:09.86: [ 6445]: --> [5:ERROR]
Mar 17 01:35:09.86: [ 6445]: SEND recv RTN (retrain negative)
Mar 17 01:35:09.86: [ 6445]: <-- [7:AT+FKS\r]
Mar 17 01:35:11.34: [ 6445]: --> [7:+FHS:02]
Mar 17 01:35:11.34: [ 6445]: REMOTE HANGUP: Call aborted,  from +FK or <CAN>
(code 2)
Mar 17 01:35:11.34: [ 6445]: --> [5:ERROR]
Mar 17 01:35:11.34: [ 6445]: MODEM Command error
Mar 17 01:35:11.34: [ 6445]: <-- [5:ATH0\r]
Mar 17 01:35:11.74: [ 6445]: --> [10:NO CARRIER]
Mar 17 01:35:11.74: [ 6445]: MODEM No carrier
Mar 17 01:35:11.75: [ 6445]: SESSION END

----------------------------------------------------------------------------
----------------------------------------------

Here is my modem config:
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:  Class2.0 # use class 2.0 interface
ModemRate:  38400  # 38.4 works fine
ModemFlowControl: rtscts  # default
#
ModemNoFlowCmd:  AT&H0  # disable flow control
ModemHardFlowCmd: AT&H3  # hardware flow control
ModemSoftFlowCmd: AT&H4  # software flow control
ModemSetupDTRCmd: AT&D2  # DTR off causes modem to hang up
ModemSetupDCDCmd: AT&C1  # DCD tracks carrier
#
ModemSetupAACmd: AT+FAA=1 # enable in current class
#
# Additional reset commands:
#
# &B1   DTE-DCE rate is fixed at DTE setting
# &N0   Auto-negotiate highest possible DCE-DCE link rate
# &S0   DSR always on
# *F0   Deny remote configuration
# S18=2   Receive at 38400
# S38.3=1 DCD on/off sequence follows UNIX standard; also
#   fix receiving baud rate at S18 value
# S39=0   (avoid Class 2 compatibility hacks)
#
ModemResetCmds:  AT&B1&N0&S0*F0S18=2S38.3=1S39=0
#
ModemDialCmd:  ATDT%s  # no '@' 'cuz then busy not recognized
NoCarrierRetrys: 3  # retry 3 times on no carrier
#
ModemSetVolumeCmd: "ATM0 ATM1L1 ATM1L3 ATM1L5 ATM1L7"
#
# Caller ID configuration setup.
#
#QualifyCID:  etc/cid  # CID access control list file
#CIDNumber:  "CALLER NUMBER: " # pattern string for phone number info
#CIDName:  "CALLER NAME: " # pattern string for identity info
#
PagerSetupCmds:  AT&K0&N15 # use V.22 at 1200 bps (PageNet)
#
# Rev 6.1x firmware have a bug in the ECM support so
# explicitly disable it's use.  To re-enable its use just
# comment out the following line.
#
Class2DCCQueryCmd: "!(0,1),(0-5),(0-4),(0-2),(0,1),(0),(0),(0-7)"
----------------------------------------------------------------------------
------------------------------

Greetings

Please replay to gruenig@tecnosoft.ch