Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
RE: MultiTech MT2834ZDXV recommendation?
What I would do:
0) Check with manufacturer to see if this is a know problem and try to
get a later firmware release, revision.
1) Change the modem and use an new one same model
2) If problem persists, change FLID to a numeric string and check again
3) If the problems still persists commit Hara_Kiri.....
Please keep me posted on this subject, I am buying this modem for my
system.
Julio
On Wed, 22 Oct 1997, David Birnbaum wrote:
> I just checked my config file, and it is identical. Here is a sample
> failure trace:
>
> Oct 02 19:47:36.55: [ 8646]: SESSION BEGIN 00001980 12126331423
> Oct 02 19:47:36.55: [ 8646]: SEND FAX: JOB 2665 DEST 6331423 COMMID 00001980
> Oct 02 19:47:36.55: [ 8646]: DELAY 2600 ms
> Oct 02 19:47:39.15: [ 8646]: <-- [15:ATE0V1Q0S0=0H0\r]
> Oct 02 19:47:39.40: [ 8646]: --> [14:ATE0V1Q0S0=0H0]
> Oct 02 19:47:39.51: [ 8646]: --> [2:OK]
> Oct 02 19:47:39.51: [ 8646]: <-- [21:ATS8=2S7=60&E4&D3&C1\r]
> Oct 02 19:47:39.83: [ 8646]: --> [2:OK]
> Oct 02 19:47:39.83: [ 8646]: <-- [12:AT+FCLASS=2\r]
> Oct 02 19:47:40.15: [ 8646]: --> [2:OK]
> Oct 02 19:47:40.15: [ 8646]: <-- [10:AT+FTBC=0\r]
> Oct 02 19:47:40.47: [ 8646]: --> [2:OK]
> Oct 02 19:47:40.47: [ 8646]: <-- [10:AT+FBOR=0\r]
> Oct 02 19:47:40.79: [ 8646]: --> [2:OK]
> Oct 02 19:47:40.79: [ 8646]: <-- [13:AT+FPHCTO=30\r]
> Oct 02 19:47:41.10: [ 8646]: --> [2:OK]
> Oct 02 19:47:41.11: [ 8646]: <-- [24:AT+FDCC=1,5,2,2,0,0,0,0\r]
> Oct 02 19:47:41.43: [ 8646]: --> [2:OK]
> Oct 02 19:47:41.43: [ 8646]: <-- [5:ATM0\r]
> Oct 02 19:47:41.75: [ 8646]: --> [2:OK]
> Oct 02 19:47:41.82: [ 8646]: <-- [12:AT+FCLASS=2\r]
> Oct 02 19:47:42.23: [ 8646]: --> [2:OK]
> Oct 02 19:47:42.24: [ 8646]: <-- [10:AT+FTBC=0\r]
> Oct 02 19:47:42.64: [ 8646]: --> [2:OK]
> Oct 02 19:47:42.65: [ 8646]: <-- [10:AT+FBOR=0\r]
> Oct 02 19:47:43.05: [ 8646]: --> [2:OK]
> Oct 02 19:47:43.06: [ 8646]: <-- [13:AT+FPHCTO=30\r]
> Oct 02 19:47:43.46: [ 8646]: --> [2:OK]
> Oct 02 19:47:43.47: [ 8646]: <-- [24:AT+FDCC=1,5,2,2,0,0,0,0\r]
> Oct 02 19:47:43.88: [ 8646]: --> [2:OK]
> Oct 02 19:47:43.89: [ 8646]: <-- [27:AT+FLID="CHELSEA NETWORKS"\r]
> Oct 02 19:48:13.90: [ 8646]: MODEM <Timeout>
> Oct 02 19:48:13.90: [ 8646]: SEND FAILED: Unable to configure modem for fax use
> Oct 02 19:48:13.91: [ 8646]: SESSION END
>
> Note the timeout. I know there are some issues with setting the ID to a
> non-numeric parameter, but the fact that it works 97 times out of a
> hundred is what is so strange about it.
>
> USR users - does anybody actually use the USR chassis for faxing? I have
> a MP 8 that I was going to use, but all of the notes from people about USR
> problems has me a bit nervous.
>
> Incidently, I sent out 600-700 faxes a night using only two modems right
> now....
>
> David.
>
> On Wed, 22 Oct 1997, Patrick Gardella wrote:
>
> > I do send 2000+ a day. Our record day is 4041 in 24 hours on 7 modems. All the
> > faxes are 1 to 2 pages, no cover sheets and all are US (local) numbers.
> >
> > Here is my config file for one of the modems: (The FAXnumber and LocalId are
> > commented out :)
> >
> >
> > Patrick
> > _________________
> >
> > CountryCode: 1
> > AreaCode: 703
> > FAXNumber: +xxxxx
> > LongDistancePrefix: 1
> > InternationalPrefix: 011
> > DialStringRules: "etc/dialrules"
> > ServerTracing: 1
> > SessionTracing: 11
> > RecvFileMode: 0600
> > LogFileMode: 0600
> > DeviceMode: 0660
> > RingsBeforeAnswer: 0
> > SpeakerVolume: off
> > GettyArgs: "std.%s"
> > LocalIdentifier: "xxxx"
> > TagLineFont: etc/lutRS18.pcf
> > TagLineFormat: "From %%l|%c|Page %%p of %%t"
> > MaxRecvPages: 25
> > #
> > #
> > # Modem-related stuff: should reflect modem command interface
> > # and hardware connection/cabling (e.g. flow control).
> > #
> > ModemType: Class2 # use class 2 interface
> > ModemRate: 38400 # lock rate for DCE-DTE communication
> > ModemFlowControl: rtscts # default
> > #
> > ModemHardFlowCmd: AT&E4 # hardware flow control
> > ModemSoftFlowCmd: AT&E5 # software flow control
> > ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem
> > ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
> > ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in class 2
> > #
> > # NB: some models get confused by the @
> > #
> > ModemDialCmd: ATDT%s@ # T for tone dialing, @ for silence
> > #
> > Class2RecvDataTrigger: "\022" # character sent to modem to start recv
> >
> >
> > On 22-Oct-97 Prof. Julio C. Spinelli wrote:
> > >Dear Patrick,
> > >
> > >Could you please provide me with the config file that you are using. I
> > >would like to try the Multitech modem. Do you really send 2000 faxes per
> > >day average? Whow! Are they all to the USA or international?
> > >
> > >Thanks very much for this help,
> > >
> > >Modem vendors will learn to market products that really work thaks to the
> > >exchange of info that you are doing. Thanks again,
> > >
> > >Julio
> > >
> > >On Wed, 22 Oct 1997, Patrick Gardella wrote:
> > >
> > >> I am using 8 MT2834ZDX modems are they have not given me a problem yet! What
> > >> is the "v" mean? It this the 28.8 -33.6 update?
> > >>
> > >> Been running 24x7 for 3 months at an average of 2000 faxes outgoing. (I don't
> > >> allow any incoming.)
> > >>
> > >> Patrick
> > >>
> > >> On 21-Oct-97 Larry Pyeatt wrote:
> > >> >Hello,
> > >> > I have given up on my USR Sportster and am looking for a modem that
> > >> >works.
> > >> >Has anyone used the MT2834ZDXV with hylafax? If so, does it work well?
> > >> >
> > >> >Thanks.
> > >> >
> > >> >--
> > >> >Larry D. Pyeatt All standard disclaimers apply.
> > >> >pyeatt@cs.colostate.edu Void where prohibited.
> > >> >http://www.cs.colostate.edu/~pyeatt
> > >>
> >
>