Re: [hylafax-users] T.30 T2 timeout, expected page not received



Andy Tran wrote:

Anyone know what the following error mean or how to fix it? I am using a
USR Sporster 28,800. Thanks.


bad lines, 0 consecutive bad lines Jun 03 01:00:56.17: [ 1833]: RECV: end
page
Jun 03 01:00:56.17: [ 1833]: --> [10:NO CARRIER]
Jun 03 01:00:56.17: [ 1833]: MODEM set XON/XOFF/DRAIN: input ignored,
output disabled Jun 03 01:00:56.17: [ 1833]: MODEM input buffering
disabled
Jun 03 01:00:56.17: [ 1833]: <-- [9:AT+FRH=3\r]
Jun 03 01:00:56.69: [ 1833]: --> [7:CONNECT]
Jun 03 01:01:01.69: [ 1833]: MODEM TIMEOUT: receiving HDLC frame data Jun
03 01:01:01.70: [ 1833]: --> [2:OK]
Jun 03 01:01:01.70: [ 1833]: RECV keeping unconfirmed page



This means that connectivity was lost with the remote.


It probably hung up.

Have you contacted the sender to find out what they saw on their end. Are you sure they didn't cancel?