Re: [hylafax-users] Send but no recieve
Did you rerun init? Ie, init q?
--- alban Coujard <acoujard@xxxxxxxxxxx> wrote:
> Hello
>
> I used a USR Sportster Voice 33.6 Fax Modem, I can
> send Fax but Can't
> receive... On a mandrake 10.1, the modem is on the
> serial port 2 (ttyS1),
> hylafax 4.2,
>
> I dont forget to do #faxgetty ttyS1
>
> My config.ttyS1 file is :
>
> CountryCode: 33
> AreaCode: 3
> FAXNumber: +33.03.xxxxxxxx
> LongDistancePrefix: 0
> InternationalPrefix: 00
> DialStringRules: etc/dialrules
> ServerTracing: 1
> SessionTracing: 11
> RecvFileMode: 0600
> LogFileMode: 0600
> DeviceMode: 0600
> RingsBeforeAnswer: 1
> SpeakerVolume: quiet
> GettyArgs: "-h %l dx_%s"
> LocalIdentifier: "NothingSetup"
> TagLineFont: etc/lutRS18.pcf
> TagLineFormat: "From %%l|%c|Page %%P of %%T"
> MaxRecvPages: 25
> #
> #
> # Modem-related stuff: should reflect modem command
> interface
> # and hardware connection/cabling (e.g. flow
> control).
> #
> ModemType: Class1 # use class 1 interface
> ModemRate: 19200 # rate for DCE-DTE communication
> ModemFlowControl: xonxoff # software flow control
> #
> ModemSetupDTRCmd: ATS13=1&D2 # setup so DTR drop
> resets modem
> ModemSetupDCDCmd: AT&C1 # setup so DCD reflects
> carrier (or not)
> ModemNoFlowCmd: AT&H0&I0&R1 # setup modem for no
> flow control
> ModemHardFlowCmd: AT&H1&I0&R2 # setup modem for
> hardware flow control
> ModemSoftFlowCmd: AT&H2&I2&R1 # setup modem for
> software flow control
> ModemResultCodesCmd: ATQ0X4 # enable result codes
> #
> ModemMfrQueryCmd: !USR
> ModemModelQueryCmd: ATI3
> ModemRevQueryCmd: ATI7 # XXX returns a multi-line
> result
> #
> # When AT+FCLASS=1 is issued the modem automatically
> switches
> # to software flow control; these parameters let the
> fax software
> # reset flow control as needed after entering Class
> 1.
> #
> Class1NFLOCmd: AT&H0&I0&R1 # setup modem for no
> flow control
> Class1HFLOCmd: AT&H1&I0&R2 # setup modem for
> hardware flow control
> Class1SFLOCmd: "" # modem does this automatically
> #
> # This should resolve "DIS/DTC received 3 times"
> errors:
> #
> Class1ResponseWaitCmd: AT+FRS=1 # wait after sending
> TCF for response
> #
> # The remainder of this configuration is included so
> that the
> # modem "idles" in Class 0 while not sending or
> receiving facsimile.
> #
> ModemSetupAACmd: AT+FCLASS=0 # leave modem idling in
> class 0
> ModemAnswerCmd: AT+FCLASS=1A # answer in Class 1
> #
> # Disables the reporting of bad frames by the modem.
> This
> # overcomes a firmware problem in the x2 and V90
> Sportsters.
> # It is not necessary for the Courier modem.
> #
> Class2NRCmd: AT+FNR=1,1,1,0
>
> probemodem command result is :
>
> This looks like a Class 1 and 2.0 modem.
>
> ATI0 RESULT = "OK" RESPONSE = "3361"
> ATI1 RESULT = "OK" RESPONSE = "966D"
> ATI2 RESULT = "OK" RESPONSE = "OK"
> ATI3 RESULT = "OK" RESPONSE = "USRobotics
> Sportster Voice 33600 Fax Rev.
> 2.0"
> ATI4 RESULT = "OK" RESPONSE = "USRobotics
> Sportster Voice 33600 Fax
> Settings..."
> ATI5 RESULT = "Strike a key when ready . . ."
> RESPONSE = "USRobotics
> Sportster Voice 33600 Fax NVRAM Settings..."
> ATI6 RESULT = "OK" RESPONSE = "USRobotics
> Sportster Voice 33600 Fax Link
> Diagnostics..."
> ATI7 RESULT = "OK" RESPONSE = "Configuration
> Profile..."
> ATI8 RESULT = "OK" RESPONSE = "Blacklist"
> ATI9 RESULT = "OK" RESPONSE =
> "(1.0USR0007\Modem\Sportster 33600
> FAX/VOICE EXT)FF"
>
> Class 1 stuff...
>
> AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,2.0"
> AT+FCLASS? RESULT = "OK" RESPONSE = "0"
> AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
> AT+FCLASS=1 RESULT = "OK" RESPONSE = "OK"
> AT+FCLASS? RESULT = "OK" RESPONSE = "1"
> AT+FJUNK=? RESULT = "ERROR" RESPONSE =
> "ERROR"
> AT+FJUNK? RESULT = "ERROR" RESPONSE =
> "ERROR"
> AT+FAA=? RESULT = "OK" RESPONSE = "(0,1)"
> AT+FAA? RESULT = "OK" RESPONSE = "0"
> AT+FAE=? RESULT = "ERROR" RESPONSE =
> "ERROR"
> AT+FAE? RESULT = "ERROR" RESPONSE = "ERROR"
> AT+FTH=? RESULT = "OK" RESPONSE =
> "3,24,48,72,73,74,96,97,98,121,122,145,146"
> AT+FRH=? RESULT = "OK" RESPONSE =
> "3,24,48,72,73,74,96,97,98,121,122,145,146"
> AT+FTM=? RESULT = "OK" RESPONSE =
> "3,24,48,72,73,74,96,97,98,121,122,145,146"
> AT+FRM=? RESULT = "OK" RESPONSE =
> "3,24,48,72,73,74,96,97,98,121,122,145,146"
> AT+FTS=? RESULT = "ERROR" RESPONSE =
> "ERROR"
> AT+FRS=? RESULT = "ERROR" RESPONSE =
> "ERROR"
> Class 2.0 stuff...
>
> AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,2.0"
> AT+FCLASS? RESULT = "OK" RESPONSE = "1"
> AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
> AT+FCLASS=1 RESULT = "OK" RESPONSE = "OK"
> AT+FCLASS=2.0 RESULT = "OK" RESPONSE = "OK"
> AT+FCLASS? RESULT = "OK" RESPONSE = "1"
> AT+FJU=? RESULT = "ERROR" RESPONSE =
> "ERROR"
> AT+FJU? RESULT = "ERROR" RESPONSE = "ERROR"
> AT+FDR=? RESULT = "" RESPONSE = ""
> AT+FDT=? RESULT = "" RESPONSE = ""
> AT+FIP=? RESULT = "ERROR" RESPONSE =
> "ERROR"
> AT+FAA=? RESULT = "OK" RESPONSE = "(0,1)"
> AT+FAA? RESULT = "OK" RESPONSE = "0"
> AT+FAP=? RESULT = "ERROR" RESPONSE =
> "ERROR"
> AT+FAP? RESULT = "ERROR" RESPONSE = "ERROR"
> AT+FBS? RESULT = "OK" RESPONSE = "1800,4000"
> AT+FBO=? RESULT = "OK" RESPONSE = "(0,1)"
> AT+FBO? RESULT = "OK" RESPONSE = "0"
> AT+FBU=? RESULT = "OK" RESPONSE = "0"
> AT+FBU? RESULT = "OK" RESPONSE = "0"
> AT+FCC=? RESULT = "OK" RESPONSE =
> "(0,1),(0-5),(0-2),(0-2),0,0,0,
> (0-7)"
> AT+FCC? RESULT = "OK" RESPONSE = "1,5,0,2,0,0,0,5"
> AT+FCQ=? RESULT = "OK" RESPONSE =
> "(0-2),(0-2)"
> AT+FCQ? RESULT = "OK" RESPONSE = "1,0"
> AT+FCR=? RESULT = "OK" RESPONSE = "(0,1)"
> AT+FCR? RESULT = "OK" RESPONSE = "1"
> AT+FCS=? RESULT = "ERROR" RESPONSE =
> "ERROR"
> AT+FCS? RESULT = "OK" RESPONSE = "0,0,0,0,0,0,0,0"
> AT+FCT=? RESULT = "OK" RESPONSE = "(0-255)"
> AT+FCT? RESULT = "OK" RESPONSE = "0"
> AT+FEA=? RESULT = "OK" RESPONSE = "0"
> AT+FEA? RESULT = "OK" RESPONSE = "0"
> AT+FFC=? RESULT = "OK" RESPONSE = "0,0,0,0"
> AT+FFC? RESULT = "OK" RESPONSE = "0,0,0,0"
> AT+FFD=? RESULT = "ERROR" RESPONSE =
> "ERROR"
> AT+FFD? RESULT = "ERROR" RESPONSE = "ERROR"
> AT+FHS? RESULT = "OK" RESPONSE = "0"
> AT+FIE=? RESULT = "OK" RESPONSE = "0"
> AT+FIE? RESULT = "OK" RESPONSE = "0"
> AT+FIS=? RESULT = "OK" RESPONSE =
> "(0,1),(0-5),(0-2),(0-2),0,0,0,
> (0-7)"
> AT+FIS? RESULT = "OK" RESPONSE = "1,5,0,2,0,0,0,5"
>
=== message truncated ===
__________________________________
Discover Yahoo!
Find restaurants, movies, travel and more fun for the weekend. Check it out!
http://discover.yahoo.com/weekend.html
____________________ HylaFAX(tm) Users Mailing List _______________________
To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null
*To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx*