Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
Re: [hylafax-users] [hylafax-users]: How to tell hylafax to skip a job that doesn' t work?
> >Nov 29 16:57:07.65: [16366]: SEND begin page
> >Nov 29 16:57:07.65: [16366]: <-- data [1025]
> >Nov 29 16:57:07.65: [16366]: <-- data [1026]
> >Nov 29 16:57:07.65: [16366]: <-- data [1027]
> >Nov 29 16:57:07.65: [16366]: <-- data [1031]
> >Nov 29 16:57:07.65: [16366]: <-- data [1034]
> >Nov 29 16:57:08.90: [16366]: <-- data [1025]
> >Nov 29 16:58:28.90: [16366]: MODEM WRITE SHORT: sent 1025, wrote 232
>
> Usually this indicates a driver/firmware problem. It means that we
> told the modem to transmit 1025 bytes but the modem only responded with
> a write-count of 232.
Looks like possible a flow-control error as well...
Have you tried both software and hardware flow control (ModemFlowControl
in many hylafax-config)
a.
--
Aidan Van Dyk aidan@xxxxxxxx
Senior Software Developer +1 215 438-4638 x8103
iFAX Solutions, Inc. http://www.ifax.com/
Attachment:
pgp00013.pgp
Description: PGP signature