Lee Howard wrote:
Firstly let me point out that I *strongly* doubt that the Diva Server
will allow you to disable copy-quality checking on the modem. Thus,
"Copy quality checking performed by host" is not accurate and could
get you into trouble if ever the modem says RTN but HylaFAX CQ does not.
If you didn't read the README that comes with 4.2.0, then you missed
this part:
* Due to tighter adherance to the Class 2 specifications, HylaFAX copy-
quality checking now operates slightly different in Class 2/2.0/2.1
than
in previous versions. This change will not effect users of most
modems,
but users of the Eicon Diva Server will probably need to add
"Class2ECMType: 2.0" to their respective modem config files.
If you haven't, then I recommend that you do this. If you have, then
we have a problem still with the codebase.
It was already done when that log was taken, also i didint mention
before the version is HylaFAX (tm) Version 4.2.0beta1
/etc/hylafax# grep Class2ECMType *
config.ttyds01:Class2ECMType: 2.0 # follows Class 2.0
spec, not Class 2
config.ttyds02:Class2ECMType: 2.0 # follows Class 2.0
spec, not Class 2
config.ttyds03:Class2ECMType: 2.0 # follows Class 2.0
spec, not Class 2
config.ttyds04:Class2ECMType: 2.0 # follows Class 2.0
spec, not Class 2
<>
Jun 09 13:21:08.84: [ 1023]: <-- [7:AT+FDR\r]
Jun 09 13:21:08.94: [ 1023]: --> [7:CONNECT]
Jun 09 13:21:08.94: [ 1023]: RECV: begin page
Jun 09 13:21:08.94: [ 1023]: RECV: send trigger 021
Jun 09 13:21:08.94: [ 1023]: Copy quality checking performed by host
Jun 09 13:21:31.82: [ 1023]: RECV: 0 total lines, 0 bad lines, 0
consecutive bad lines
> This indicates that either the remote sent no data at all, or the
modem isn't delivering any data to HylaFAX at all. The latter is
probably the case, and the modem is probably performing ECM and CQ, but
because the Diva Server hides everything from us, it's really hard to
say with just a log.
> Jun 09 13:21:31.92: [ 1023]: <-- [7:AT+FDR\r]
> Jun 09 13:21:43.59: [ 1023]: --> [10:+FHNG: 100]
> Jun 09 13:21:43.59: [ 1023]: REMOTE HANGUP: Unspecified Phase D error
(code 100)
And what this probably means is that the remote did not want to
retrain and resend the page, and so it hung up. The error message
would be accurate, then, and if there is any fix to be made for any
reproducible problems, it would have to be done by Eicon.
So the problem is not on hylafax, but in firmware or drivers.
Thanks
Pablo Alcubilla.