[hylafax-users] the modem is blocked



Hello,
Once again I come to ask you for your assistance on HylaFax
We received since May 16200 faxes what proves that that functions
But I always have this problem of blocking intermitent of modem and I do not know how to solve it
the modem is blocked and I am to make the order fuser -k /dev/ttySx to release the port modem
attached the file of config and the file log
 
the modems are USROBOTICS 56K EXT
 
By Avance I thank you
Yves
 
The config.ttySx file
#
# Configuration for using the Class 1 command interface with
# a USR Courier or Sportster modem and XON/XOFF flow control.
#
#
CountryCode:  33
AreaCode:  
FAXNumber:  "01 XX XX XX XX"
LongDistancePrefix: 
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing:  1
SessionTracing:  11
RecvFileMode:  0600
LogFileMode:  0600
DeviceMode:  0600
RingsBeforeAnswer: 1
SpeakerVolume:  off
GettyArgs:  "-h %l dx_%s"
LocalIdentifier: "Fax XXXXXXXX"
TagLineFont:  etc/lutRS18.pcf
TagLineFormat:  "From %%l|%c|Page %%P of %%T"
MaxRecvPages:  25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:  Class1  # use class 1 interface
ModemRate:  19200  # max rate for DCE-DTE communication
ModemFlowControl: rtscts  # hardware flow control
#
ModemSetupDTRCmd: ATS13=1&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1  # setup so DCD reflects carrier (or not)
ModemNoFlowCmd:  AT&H0&I0&R1 # setup modem for no flow control
ModemHardFlowCmd: AT&H1&I0&R2 # setup modem for hardware flow control
ModemSoftFlowCmd: AT&H2&I2&R1 # setup modem for software flow control
ModemResultCodesCmd: ATQ0X4  # enable result codes
#
ModemMfrQueryCmd: !USR
ModemModelQueryCmd: ATI3
#ModemRevQueryCmd: ATI7  # XXX returns a multi-line result
#ModemDialCmd:           ATDT0,%s
#
# When AT+FCLASS=1 is issued the modem automatically switches
# to software flow control; these parameters let the fax software
# reset flow control as needed after entering Class 1.
#
Class1NFLOCmd:  AT&H0&I0&R1 # setup modem for no flow control
Class1HFLOCmd:  AT&H1&I0&R2 # setup modem for hardware flow control
Class1SFLOCmd:  ""  # modem does this automatically
 
#
# The remainder of this configuration is included so that the
# modem "idles" in Class 0 while not sending or receiving facsimile.
#
ModemSetupAACmd: AT+FCLASS=0&H1&I0&R2 # leave modem idling in class 0
ModemAnswerCmd:  AT+FCLASS=1&H1&I0&R2A # answer in Class 1
#
# Disables the reporting of bad frames by the modem.  This
# overcomes a firmware problem in the x2 and V90 Sportsters.
# It is not necessary for the Courier modem.
#
Class2NRCmd:    AT+FNR=1,1,1,0
The file Log
 
Dec 04 14:26:35.94: [10052]: SESSION BEGIN 00018301 0XXXXXXXXXXX
Dec 04 14:26:35.94: [10052]: HylaFAX (tm) Version 4.1.3
Dec 04 14:26:35.94: [10052]: <-- [22:AT+FCLASS=1&H1&I0&R2A\r]
Dec 04 14:26:41.24: [10052]: --> [7:CONNECT]
Dec 04 14:26:41.24: [10052]: ANSWER: FAX CONNECTION  DEVICE '/dev/ttyS7'
Dec 04 14:26:41.24: [10052]: RECV FAX: begin
Dec 04 14:26:41.24: [10052]: <-- data [23]
Dec 04 14:26:41.24: [10052]: <-- data [2]
Dec 04 14:26:41.27: [10052]: --> [7:CONNECT]
Dec 04 14:26:41.27: [10052]: <-- data [10]
Dec 04 14:26:41.27: [10052]: <-- data [2]
Dec 04 14:26:43.22: [10052]: --> [2:OK]
Dec 04 14:26:43.22: [10052]: <-- [9:AT+FRH=3\r]
Dec 04 14:26:44.95: [10052]: --> [7:CONNECT]
Dec 04 14:26:46.52: [10052]: --> [2:OK]
Dec 04 14:26:46.52: [10052]: REMOTE TSI "33 X XX XX XX XX"
Dec 04 14:26:46.52: [10052]: <-- [9:AT+FRH=3\r]
Dec 04 14:26:46.54: [10052]: --> [7:CONNECT]
Dec 04 14:26:46.79: [10052]: --> [2:OK]
Dec 04 14:26:46.79: [10052]: REMOTE wants 14400 bit/s
Dec 04 14:26:46.79: [10052]: REMOTE wants page width 1728 pixels in 215 mm
Dec 04 14:26:46.79: [10052]: REMOTE wants unlimited page length
Dec 04 14:26:46.79: [10052]: REMOTE wants 3.85 line/mm
Dec 04 14:26:46.79: [10052]: REMOTE wants 2-D MR
Dec 04 14:26:46.79: [10052]: RECV training at v.17 14400 bit/s
Dec 04 14:26:46.79: [10052]: <-- [11:AT+FRM=145\r]
Dec 04 14:26:48.49: [10052]: --> [7:CONNECT]
Dec 04 14:26:49.95: [10052]: RECV: TCF 2632 bytes, 0% non-zero, 2605 zero-run
Dec 04 14:26:49.96: [10052]: --> [10:NO CARRIER]
Dec 04 14:26:49.96: [10052]: DELAY 75 ms
Dec 04 14:26:50.04: [10052]: TRAINING succeeded
Dec 04 14:26:50.04: [10052]: <-- [9:AT+FTH=3\r]
Dec 04 14:26:50.24: [10052]: --> [7:CONNECT]
Dec 04 14:26:50.24: [10052]: <-- data [3]
Dec 04 14:26:50.24: [10052]: <-- data [2]
Dec 04 14:26:51.41: [10052]: --> [2:OK]
Dec 04 14:26:51.41: [10052]: <-- [11:AT+FRM=146\r]
Dec 04 14:26:53.10: [10052]: --> [7:CONNECT]
Dec 04 14:26:53.10: [10052]: RECV: begin page
Dec 04 14:27:01.65: [10052]: RECV: 1116 total lines, 0 bad lines, 0 consecutive bad lines
Dec 04 14:27:01.65: [10052]: RECV: end page
Dec 04 14:27:01.65: [10052]: --> [10:NO CARRIER]
Dec 04 14:27:01.65: [10052]: <-- [9:AT+FRH=3\r]
Dec 04 14:27:01.75: [10052]: --> [7:CONNECT]
Dec 04 14:27:02.71: [10052]: --> [2:OK]
Dec 04 14:27:02.71: [10052]: RECV recv MPS (more pages, same document)
Dec 04 14:27:02.71: [10052]: <-- [9:AT+FRS=7\r]
Dec 04 14:27:02.81: [10052]: --> [2:OK]
Dec 04 14:27:02.81: [10052]: <-- [9:AT+FTH=3\r]
Dec 04 14:27:32.81: [10052]: MODEM <Timeout>
Dec 04 14:27:32.81: [10052]: RECV send MCF (message confirmation)
Dec 04 14:27:32.81: [10052]: RECV FAX (00018301): from 33 1 XX XX XX XX, page 1 in 0:42, INF, 3.85 line/mm, 2-D MR, 14400 bit/s
Dec 04 14:27:32.81: [10052]: <-- data [3]
Dec 04 14:27:32.81: [10052]: <-- data [2]
Dec 04 14:27:35.36: [10052]: --> [5:ÿŒ]