Hylafax Mailing List Archives

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: [hylafax-users] No response to MPS or EOP repeated 3 tries





Lee Howard wrote:

(..)
> and the output of probemodem <device>.

Sorry, I forgot that. Here it comes:

---------
Now we are going to probe the tty port.  This takes a few seconds,
so be patient.  Note that if you do not have the modem cabled to
the port, or the modem is turned off, this may hang (just go and
cable up the modem or turn it on, or whatever).

Probing for best speed to talk to modem: 38400 OK.
[1]+  Terminated              ( trap 0 1 2; while true; do
     sleep 10; echo ""; echo "Hmm, something seems to be hung, check 
your modem eh?";
done )

This looks like a Class 1+2+2.0 modem.

ATI0 
RESULT = "OK"	RESPONSE = "28642"
ATI1 
RESULT = "OK"	RESPONSE = "Elite 2864I DSS1:  V 3.01"
ATI2 
RESULT = "OK"	RESPONSE = "   ZyXEL MODEMS LINK STATUS REPORT"
ATI3 
RESULT = "OK"	RESPONSE = "ZyXEL ISDN MODEM LINK STATUS REPORT"

Class 1 stuff...

AT+FCLASS=? 
RESULT = "OK"	RESPONSE = "0,1,2,2.0,6,8,Z"
AT+FCLASS? 
RESULT = "OK"	RESPONSE = "1"
AT+FCLASS=0 
RESULT = "OK"	RESPONSE = "OK"
AT+FCLASS=1 
RESULT = "OK"	RESPONSE = "OK"
AT+FCLASS? 
RESULT = "OK"	RESPONSE = "1"
AT+FJUNK=? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FJUNK? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FAA=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FAA? 
RESULT = "OK"	RESPONSE = "0"
AT+FAE=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FAE? 
RESULT = "OK"	RESPONSE = "0"
AT+FTH=? 
RESULT = "OK"	RESPONSE = "3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FRH=? 
RESULT = "OK"	RESPONSE = "3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FTM=? 
RESULT = "OK"	RESPONSE = "3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FRM=? 
RESULT = "OK"	RESPONSE = "3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FTS=? 
RESULT = "OK"	RESPONSE = "0-255"
AT+FRS=? 
RESULT = "OK"	RESPONSE = "0-255"

Class 2 stuff...

AT+FCLASS=? 
RESULT = "OK"	RESPONSE = "0,1,2,2.0,6,8,Z"
AT+FCLASS? 
RESULT = "OK"	RESPONSE = "1"
AT+FCLASS=0 
RESULT = "OK"	RESPONSE = "OK"
AT+FCLASS=1 
RESULT = "OK"	RESPONSE = "OK"
AT+FCLASS=2 
RESULT = "OK"	RESPONSE = "OK"
AT+FCLASS? 
RESULT = "OK"	RESPONSE = "2"
AT+FJUNK=? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FJUNK? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FAA=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FAA? 
RESULT = "OK"	RESPONSE = "0"
AT+FAXERR=? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FAXERR? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FBADLIN=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FBADLIN? 
RESULT = "OK"	RESPONSE = "OK"
AT+FBADMUL=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FBADMUL? 
RESULT = "OK"	RESPONSE = "OK"
AT+FBOR=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FBOR? 
RESULT = "OK"	RESPONSE = "0"
AT+FBUF=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FBUF? 
RESULT = "OK"	RESPONSE = "OK"
AT+FBUG=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FBUG? 
RESULT = "OK"	RESPONSE = "OK"
AT+FCIG=? 
RESULT = "OK"	RESPONSE = "20-7E"
AT+FCIG? 
RESULT = "OK"	RESPONSE = "OK"
AT+FCQ=? 
RESULT = "OK"	RESPONSE = "0-2"
AT+FCQ? 
RESULT = "OK"	RESPONSE = "1"
AT+FCR=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FCR? 
RESULT = "OK"	RESPONSE = "0"
AT+FTBC=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FTBC? 
RESULT = "OK"	RESPONSE = "OK"
AT+FDCC=? 
RESULT = "OK"	RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0,1),(0),(0),(0-7)"
AT+FDCC? 
RESULT = "OK"	RESPONSE = "1,5,0,2,0,0,0,0"
AT+FDCS=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FDCS? 
RESULT = "OK"	RESPONSE = "OK"
AT+FDIS=? 
RESULT = "OK"	RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0,1),(0),(0),(0-7)"
AT+FDIS? 
RESULT = "OK"	RESPONSE = "1,5,0,2,0,0,0,0"
AT+FDT=? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FDT? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FECM=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FECM? 
RESULT = "OK"	RESPONSE = "OK"
AT+FET=? 
RESULT = "OK"	RESPONSE = "0,1,2,4,5,6"
AT+FET? 
RESULT = "OK"	RESPONSE = "OK"
AT+FLID=? 
RESULT = "OK"	RESPONSE = "20-7E"
AT+FLID? 
RESULT = "OK"	RESPONSE = "OK"
AT+FLNFC=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FLNFC? 
RESULT = "OK"	RESPONSE = "OK"
AT+FLPL=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FLPL? 
RESULT = "OK"	RESPONSE = "0"
AT+FMDL? 
RESULT = "OK"	RESPONSE = "E2864  V 3.00a"
AT+FMFR? 
RESULT = "OK"	RESPONSE = "ZyXEL"
AT+FMINSP=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FMINSP? 
RESULT = "OK"	RESPONSE = "OK"
AT+FPHCTO=? 
RESULT = "OK"	RESPONSE = "0-255"
AT+FPHCTO? 
RESULT = "OK"	RESPONSE = "30"
AT+FPTS=? 
RESULT = "OK"	RESPONSE = "1-5"
AT+FPTS? 
RESULT = "OK"	RESPONSE = "1,0,0,0,0"
AT+FRBC=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FRBC? 
RESULT = "OK"	RESPONSE = "OK"
AT+FREL=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FREL? 
RESULT = "OK"	RESPONSE = "0"
AT+FREV? 
RESULT = "OK"	RESPONSE = "E2864  V 3.00a"
AT+FSPL=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FSPL? 
RESULT = "OK"	RESPONSE = "0"
AT+FTBC=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FTBC? 
RESULT = "OK"	RESPONSE = "OK"
AT+FVRFC=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FVRFC? 
RESULT = "OK"	RESPONSE = "OK"
AT+FWDFC=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FWDFC? 
RESULT = "OK"	RESPONSE = "OK"
AT+FK=? 
RESULT = "ERROR"	RESPONSE = "ERROR"

Class 2.0 stuff...

AT+FCLASS=? 
RESULT = "OK"	RESPONSE = "0,1,2,2.0,6,8,Z"
AT+FCLASS? 
RESULT = "OK"	RESPONSE = "2"
AT+FCLASS=0 
RESULT = "OK"	RESPONSE = "OK"
AT+FCLASS=1 
RESULT = "OK"	RESPONSE = "OK"
AT+FCLASS=2.0 
RESULT = "OK"	RESPONSE = "OK"
AT+FCLASS? 
RESULT = "OK"	RESPONSE = "2.0"
AT+FJU=? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FJU? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FDR=? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FDT=? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FIP=? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FAA=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FAA? 
RESULT = "OK"	RESPONSE = "0"
AT+FBS? 
RESULT = "OK"	RESPONSE = "1800,2000"
AT+FBO=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FBO? 
RESULT = "OK"	RESPONSE = "0"
AT+FBU=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FBU? 
RESULT = "OK"	RESPONSE = "OK"
AT+FCC=? 
RESULT = "OK"	RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0,1),(0),(0),(0-7)"
AT+FCC? 
RESULT = "OK"	RESPONSE = "0,5,0,2,0,0,0,0"
AT+FCQ=? 
RESULT = "OK"	RESPONSE = "(0-2),(0-2)"
AT+FCQ? 
RESULT = "OK"	RESPONSE = "0,0"
AT+FCR=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FCR? 
RESULT = "OK"	RESPONSE = "0"
AT+FCS=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FCS? 
RESULT = "OK"	RESPONSE = "OK"
AT+FCT=? 
RESULT = "OK"	RESPONSE = "0-FF"
AT+FCT? 
RESULT = "OK"	RESPONSE = "1E"
AT+FEA=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FEA? 
RESULT = "OK"	RESPONSE = "0"
AT+FFC=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FFC? 
RESULT = "OK"	RESPONSE = "OK"
AT+FHS=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FHS? 
RESULT = "OK"	RESPONSE = "OK"
AT+FIE=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FIE? 
RESULT = "OK"	RESPONSE = "0"
AT+FIS=? 
RESULT = "OK"	RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0,1),(0),(0),(0-7)"
AT+FIS? 
RESULT = "OK"	RESPONSE = "0,5,0,2,0,0,0,0"
AT+FLI=? 
RESULT = "OK"	RESPONSE = "20-7E"
AT+FLI? 
RESULT = "OK"	RESPONSE = "OK"
AT+FLO=? 
RESULT = "OK"	RESPONSE = "0-2"
AT+FLO? 
RESULT = "OK"	RESPONSE = "1"
AT+FLP=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FLP? 
RESULT = "OK"	RESPONSE = "0"
AT+FMI? 
RESULT = "OK"	RESPONSE = "ZyXEL"
AT+FMM? 
RESULT = "OK"	RESPONSE = "E2864  V 3.00a"
AT+FMR? 
RESULT = "OK"	RESPONSE = "E2864  V 3.00a"
AT+FMS=? 
RESULT = "OK"	RESPONSE = "0-5"
AT+FMS? 
RESULT = "OK"	RESPONSE = "0"
AT+FNR=? 
RESULT = "OK"	RESPONSE = "(0,1),(0,1),(0,1),(0,1)"
AT+FNR? 
RESULT = "OK"	RESPONSE = "0,0,0,0"
AT+FNS=? 
RESULT = "OK"	RESPONSE = "90"
AT+FNS? 
RESULT = "OK"	RESPONSE = "OK"
AT+FPI=? 
RESULT = "OK"	RESPONSE = "20-7E"
AT+FPI? 
RESULT = "OK"	RESPONSE = "OK"
AT+FPP=? 
RESULT = "OK"	RESPONSE = "OK"
AT+FPP? 
RESULT = "OK"	RESPONSE = "OK"
AT+FPR=? 
RESULT = "OK"	RESPONSE = "0-8,10,18,20"
AT+FPR? 
RESULT = "OK"	RESPONSE = "0"
AT+FPS=? 
RESULT = "OK"	RESPONSE = "1-5"
AT+FPS? 
RESULT = "OK"	RESPONSE = "1,0,0,0,0"
AT+FRQ=? 
RESULT = "OK"	RESPONSE = "(0-64),(0-FF)"
AT+FRQ? 
RESULT = "OK"	RESPONSE = "46,C"
AT+FRY=? 
RESULT = "OK"	RESPONSE = "0-FF"
AT+FRY? 
RESULT = "ERROR"	RESPONSE = "ERROR"
AT+FSP=? 
RESULT = "OK"	RESPONSE = "0,1"
AT+FSP? 
RESULT = "OK"	RESPONSE = "0"
AT+FKS=? 
RESULT = "ERROR"	RESPONSE = "ERROR"
-------


____________________ HylaFAX(tm) Users Mailing List _______________________
  To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
 On UNIX: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null



Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services