Re: [hylafax-users] Receive problems with ELSA 28.8 TQV



Hi Michael, use hardware flow control not xon/xoff

I attached my working config-file
don't forget to change your identifier and so on
(dialcmd is set for pabx)

HIH

Matthias


> Hi!
>
> May be any one could give me a clue? I have configured my TKR TriStar
> (which should be identical to the ELSA 28.8 TQV) as described by Michael
> Möller in http://www.hylafax.org/archive/1998-06/msg00010.html
> Seems to work fine, no errors reported in SysLog. When I start to send a
> fax to that modem via my ISDN card (in analogue mode) the call is
> received but after the first 4096 Byte is simply stops until the modem
> is set back (ISDN error code is 3114 => connection aborted by receiver).
> SysLog shows:
> Aug 23 15:02:41 gandalf FaxGetty[1335]: MODEM "" "TKR TriStar"/"Ver.
> 1.10 vom 19.09.95"
> Aug 23 15:03:46 gandalf FaxGetty[1335]: ANSWER: FAX CONNECTION
> Aug 23 15:04:23 gandalf FaxGetty[1335]: MODEM "" "TKR TriStar"/"Ver.
> 1.10 vom 19.09.95"
> logging is set to local7
> I can't figure out what is wrong. When I use my USR Courier V.Everything
> there is no problem in receiving via my ISDN card, so I guess this could
> be a problem of my configuration - what? :-((
>
> Any help appreciated - TIA :-)
>
> Maybe it helps to post my config file:
>
> --------------- soc - start of cut ---------------------
> CountryCode:            49
> AreaCode:               511
> FAXNumber:              +49.511.
> LongDistancePrefix:     0
> InternationalPrefix:    00
> DialStringRules:        etc/dialrules
> ServerTracing:          1
> SessionTracing:         11
> RecvFileMode:           0644
> LogFileMode:            0600
> DeviceMode:             0600
> RingsBeforeAnswer:      1
> SpeakerVolume:          off
> GettyArgs:              "-h %l dx_%s"
> LocalIdentifier:        "+49.511."
> LogFacility:            local7
> TagLineFont:            etc/lutRS18.pcf
> TagLineFormat:          "Von %%l|%c|Seite %%p von %%t"
> PercentGoodLines:       80
> MaxConsecutiveBadLines: 20
> MaxRecvPages:           250
> ModemPriority:          200
> #
> #
> # Modem-related stuff: should reflect modem command interface
> # and hardware connection/cabling (e.g. flow control).
> #
> ModemType:              Class2.0        # use this to supply a hint
> ModemRate:              19200           # max rate for DCE-DTE
> communication
> ModemFlowControl:       xonxoff         # XON/XOFF flow control assumed
> ModemSetupDTRCmd:       AT&D2           # setup so DTR drop resets modem
> ModemSetupDCDCmd:       AT&C1           # setup so DCD reflects carrier
> (or not)
> #
> # We normally append the "@" symbol to the dial string so that
> # the modem will wait 5 seconds before attempting to connect
> # and return result codes that distinguish between no carrier
> # and no answer.  This makes it possible to avoid problems with
> # repeatedly dialing a number that doesn't have a fax machine
> # (kudos to Stuart Lynne for this trick.)
> #
> # NB: If you need to prefix phone numbers to get through a PBX,
> #     put it in the ModemDialCmd; e.g. "DT9%s@".
> #
> ModemDialCmd:           ATDT%s
> #
> # Other possible configuration stuff.  The default strings are
> # shown below.  Only those that are different from the defaults
> # need to be included in the configuration file.
> #
> ModemResetCmds:         ATX3S130=68     # stuff to do when modem is
> reset
> ModemAnswerCmd:         ATA             # use this to answer phone
> ModemNoFlowCmd:         AT\Q0
> ModemHardFlowCmd:       AT\Q3
> ModemSoftFlowCmd:       AT\Q4
> ModemNoAutoAnswerCmd:   ATS0=0          # disable auto-answer
> #
> # Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
> # Note that we both turn the speaker on/off and set volume.
> #
> ModemSetVolumeCmd:      "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
> ModemEchoOffCmd:        ATE0            # disable command echo
> ModemVerboseResultsCmd: ATV1            # enable verbose command results
> ModemResultCodesCmd:    ATQ0            # enable result codes
> ModemOnHookCmd:         ATH0            # place phone on hook (hangup)
> ModemSoftResetCmd:      ATZ             # do soft reset of modem
> ModemWaitTimeCmd:       ATS7=60         # wait 60 seconds for carrier
> ModemCommaPauseTimeCmd: ATS8=2          # comma pause time is 2 seconds
> ModemRecvFillOrder:     LSB2MSB         # bit order of received
> facsimile
> ModemSendFillOrder:     LSB2MSB         # bit order modem expects for
> transmit
> #
> # Configuration parameters for Class 2.0 modems.
> #
> Class2Cmd:              AT+FCLASS=2.0   # command to enter class 2.0
> Class2BORCmd:           AT+FBO=0        # bit order for phase B/C/D
> (direct)
> Class2CQCmd:            ""              # commands to enable copy
> quality proc.
> Class2AbortCmd:         AT+FKS          # abort session command
> Class2CQQueryCmd:       AT+FCQ=?        # query for copy quality
> capabilities
> Class2DCCQueryCmd:      AT+FCC=?        # query for modem capabilities
> Class2TBCCmd:           AT+FPP=0        # setup stream mode
> Class2CRCmd:            AT+FCR=1        # enable capability to receive
> Class2PHCTOCmd:         AT+FCT=30       # set phase C timeout parameter
> Class2BUGCmd:           AT+FBU=1        # enable HDLC frame tracing
> Class2LIDCmd:           AT+FLI          # set local identifier command
> Class2DCCCmd:           AT+FCC          # set modem capabilities command
> Class2DISCmd:           AT+FIS          # set session parameters command
> Class2DDISCmd:          ""              # disable pre-dial DIS command
> hack
> Class2CIGCmd:           AT+FPI          # set polling identifier command
> Class2NRCmd:            AT+FNR=1,1,1,1  # setup status reporting command
> Class2PIECmd:           AT+FIE=0        # disable interrupt-enable
> command
> Class2PTSCmd:           AT+FPS          # set post-page status command
> Class2SPLCmd:           AT+FSP          # set polling indicator command
> Class2NFLOCmd:          AT+FLO=0        # set no flow control command
> Class2SFLOCmd:          AT+FLO=1        # set software flow control
> command
> Class2HFLOCmd:          AT+FLO=2        # set hardware flow control
> command
> --------------- eoc - end of cut ---------------------
>
>
>
>
> ____________________ HylaFAX(tm) Users Mailing List _______________________
>  To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org <
> /dev/null

-- 
HAGOS eG                 phone: +49 711 7880592
Matthias Reich             fax: +49 711 7880599
Industriestr. 62           web: http://www.hagos.de
D-70565 Stuttgart         mail: rei@hagos.de
Germany
# $Id: class2,v 1.23 1996/06/24 02:58:32 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
# 
# Permission to use, copy, modify, distribute, and sell this software and 
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
# 
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
# 
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
# OF THIS SOFTWARE.
#

#
# Generic Class 2 modem configuration.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode:		49
AreaCode:		711
FAXNumber:		+49.XXXXXXXXXXXX
LongDistancePrefix:	0
InternationalPrefix:	00
DialStringRules:	etc/dialrules
ServerTracing:		0
SessionTracing:		0
RecvFileMode:		0600
LogFileMode:		0600
DeviceMode:		0600
RingsBeforeAnswer:	1
SpeakerVolume:		off
GettyArgs:		"-h %l dx_%s"
LocalIdentifier:	"Meine Firma"
TagLineFont:		etc/lutRS18.pcf
TagLineFormat:		"   Von %%l|%c|Seite %%p von %%t"
QualifyTSI:		etc/tsi
MaxRecvPages:		25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:		Class2		# use this to supply a hint
ModemRate:		38400
ModemFlowControl:	rtscts
ModemSetupDTRCmd:	AT&D2		# setup so DTR drop resets modem
ModemSetupDCDCmd:	AT&C1		# setup so DCD reflects carrier (or not)
#
# We normally append the "@" symbol to the dial string so that
# the modem will wait 5 seconds before attempting to connect
# and return result codes that distinguish between no carrier
# and no answer.  This makes it possible to avoid problems with
# repeatedly dialing a number that doesn't have a fax machine
# (kudos to Stuart Lynne for this trick.)
#
# NB: If you need to prefix phone numbers to get through a PBX,
#     put it in the ModemDialCmd; e.g. "DT9%s@".
#
ModemDialCmd:		ATDT0,%s
#
# Other possible configuration stuff.  The default strings are
# shown below.  Only those that are different from the defaults
# need to be included in the configuration file.
#
ModemResetCmds:		ATX3		# stuff to do when modem is reset
ModemAnswerCmd:		ATA		# use this to answer phone
ModemNoFlowCmd:		AT\Q0		# disable flow control cmd
ModemHardFlowCmd:	AT\Q3		# hardware flow control cmd
ModemSoftFlowCmd:	AT\Q1		# software flow control cmd
ModemNoAutoAnswerCmd:	ATS0=0		# disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
ModemSetVolumeCmd:	"ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
ModemEchoOffCmd:	ATE0		# disable command echo
ModemVerboseResultsCmd:	ATV1		# enable verbose command results
ModemResultCodesCmd:	ATQ0		# enable result codes
ModemOnHookCmd:		ATH
ModemSoftResetCmd:	ATZ		# do soft reset of modem
ModemWaitTimeCmd:	ATS7=60		# wait 60 seconds for carrier
ModemCommaPauseTimeCmd:	ATS8=2		# comma pause time is 2 seconds
ModemRecvFillOrder:	LSB2MSB		# bit order of received facsimile
ModemSendFillOrder:	LSB2MSB		# bit order modem expects for transmit
#
# Configuration parameters for Class 2 modems.
#
Class2Cmd:		AT+FCLASS=2	# command to enter class 2
Class2BORCmd:		AT+FBOR=0	# bit order for phase B/C/D (direct)
Class2RELCmd:		AT+FREL=1	# byte-align EOL codes on recv
Class2CQCmd:		""		# commands to enable copy quality proc.
Class2AbortCmd:		AT+FK		# abort session command
Class2CQQueryCmd:	AT+FCQ=?	# query for copy quality capabilities
Class2DCCQueryCmd:	AT+FDCC=?	# query for modem capabilities
Class2TBCCmd:		AT+FTBC=0	# setup stream mode
Class2CRCmd:		AT+FCR=1	# enable capability to receive
Class2PHCTOCmd:		AT+FPHCTO=30	# set phase C timeout parameter
Class2BUGCmd:		AT+FBUG=1	# enable HDLC frame tracing
Class2LIDCmd:		AT+FLID		# set local identifier command
Class2DCCCmd:		AT+FDCC		# set modem capabilities command
Class2DISCmd:		AT+FDIS		# set session parameters command
Class2DDISCmd:		""		# disable pre-dial DIS command hack
Class2CIGCmd:		AT+FCIG		# set polling identifier command
Class2PTSCmd:		AT+FPTS		# set post-page status command
Class2SPLCmd:		AT+FSPL		# set polling indicator command
#
# If Class2RecvDataTrigger is not set, then it is set to DC1
#
Class2RecvDataTrigger:	""		# character sent to modem to start recv
Class2XmitWaitForXON:	yes		# if true, wait for XON before send