Re: [hylafax-users] class1 modem and modem capabilities
At 10:26 PM 7/13/01 +0200, Giulio Orsero wrote:
>hylafax-4.1 + some patches (bugzilla id: tsieop-52 eom-117 cid-139 eop-152
>bulk-153 faxqcl-160 log-51 dso-141 dest-172)
>
>Class1/rockwell modem, no particular settings in config.devid (standard
class1).
>
>ati0 -> 56000
>ati3 -> V2.083-K56_DLS
>at+fclass=? -> 0,1,1.0
>
>managed with faxgetty.
>
>2 issues:
>
>1) Why 'Supports "Class 2' ?? This is just a curiosity since the modem is
>actually used in class1 and works fine.
>
>FaxGetty[2072]: MODEM Supports "Data"
>FaxGetty[2072]: MODEM Supports "Class 1"
>FaxGetty[2072]: MODEM Supports "Class 2"
faxgetty must be misinterpreting the DCC response. Prolly somewhere here:
(faxd/Class1.c++)
/*
* Check if the modem is a Class 1 modem and,
* if so, configure it for use.
*/
bool
Class1Modem::setupModem()
{
if (!selectBaudRate(conf.maxRate, conf.flowControl, conf.flowControl))
return (false);
// Query service support information
fxStr s;
if (doQuery(conf.classQueryCmd, s, 500) && FaxModem::parseRange(s,
modemSer$
traceBits(modemServices & SERVICE_ALL, serviceNames);
if ((modemServices & SERVICE_CLASS1) == 0)
return (false);
atCmd(conf.class1Cmd);
....
As you're aware, it's not terribly bad, but it is erronious output.
>2) Why not 2-D MMR too? I think I'd save on connection time.
>...
>FaxGetty[2072]: MODEM Supports unlimited page length
>FaxGetty[2072]: MODEM Supports 1-D MR
>FaxGetty[2072]: MODEM Supports 2-D MR
Again, faxgetty is misinterpreting the DCC response somewhere near here:
(faxd/FaxModem.c++)
/*
* Trace a modem's capabilities.
*/
void
FaxModem::traceModemParams()
{
traceBits(modemParams.vr, Class2Params::verticalResNames);
traceBits(modemParams.br, Class2Params::bitRateNames);
traceBits(modemParams.wd, Class2Params::pageWidthNames);
traceBits(modemParams.ln, Class2Params::pageLengthNames);
traceBits(modemParams.df, Class2Params::dataFormatNames);
if (supportsECM())
traceBits(modemParams.ec, Class2Params::ecmNames);
if (modemParams.bf & BIT(BF_ENABLE))
modemSupports("binary file transfer");
traceBits(modemParams.st, Class2Params::scanlineTimeNames);
....
However, I highly suspect that HylaFAX is still utilizing 2-D MMR
whenever/if possible. This here is merely a listing, and not a setting.
Can you list your DCC response? (AT+FDCC=?) Does this even work on a Class
1 modem, though?
Maybe it's AT+FTM=? on a Class 1 modem...