Hylafax Mailing List Archives

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

[hylafax-users] handshake problems



Haho,

I try to send, but get unsuccessful handshake.
using the newest cvs.
The remote fax machine is an Olivetti OFX-950.
My modem is: MODEM ROCKWELL AC/K56/V2.200-V90_2M_DLS
Any suggestions?

Mar 22 11:29:57.36: [26497]: SESSION BEGIN 00030257 039059525759
Mar 22 11:29:57.36: [26497]: SEND FAX: JOB 13480 DEST 00039059525759 COMMID
00030257
Mar 22 11:29:57.36: [26497]: MODEM set DTR OFF
Mar 22 11:29:57.36: [26497]: DELAY 2600 ms
Mar 22 11:29:59.96: [26497]: MODEM set DTR ON
Mar 22 11:29:59.96: [26497]: MODEM set baud rate: 38400 baud, input flow
XON/XOFF, output flow XON/XOFF
Mar 22 11:29:59.96: [26497]: MODEM flush i/o
Mar 22 11:29:59.96: [26497]: <-- [4:ATZ\r]
Mar 22 11:30:00.09: [26497]: --> [2:OK]
Mar 22 11:30:00.09: [26497]: <-- [15:ATE0V1Q0S0=0H0\r]
Mar 22 11:30:00.10: [26497]: --> [14:ATE0V1Q0S0=0H0]
Mar 22 11:30:00.10: [26497]: --> [2:OK]
Mar 22 11:30:00.10: [26497]: <-- [21:ATS8=2S7=60&K4&D3&C1\r]
Mar 22 11:30:00.12: [26497]: --> [2:OK]
Mar 22 11:30:00.12: [26497]: <-- [12:AT+FCLASS=2\r]
Mar 22 11:30:00.13: [26497]: --> [2:OK]
Mar 22 11:30:00.13: [26497]: <-- [10:AT+FTBC=0\r]
Mar 22 11:30:00.14: [26497]: --> [2:OK]
Mar 22 11:30:00.14: [26497]: <-- [10:AT+FBOR=0\r]
Mar 22 11:30:00.15: [26497]: --> [2:OK]
Mar 22 11:30:00.15: [26497]: <-- [13:AT+FPHCTO=30\r]
Mar 22 11:30:00.16: [26497]: --> [2:OK]
Mar 22 11:30:00.16: [26497]: <-- [9:AT+FBUG=\r]
Mar 22 11:30:00.17: [26497]: --> [2:OK]
Mar 22 11:30:00.17: [26497]: <-- [24:AT+FDCC=1,5,2,2,0,0,0,0\r]
Mar 22 11:30:00.19: [26497]: --> [2:OK]
Mar 22 11:30:00.19: [26497]: <-- [5:ATM0\r]
Mar 22 11:30:00.20: [26497]: --> [2:OK]
Mar 22 11:30:00.20: [26497]: STATE CHANGE: RUNNING -> SENDING
Mar 22 11:30:00.20: [26497]: MODEM input buffering enabled
Mar 22 11:30:00.20: [26497]: Apply DialString rules to "00039059525759"
Mar 22 11:30:00.20: [26497]: --> return result "00039059525759"
Mar 22 11:30:00.20: [26497]: <-- [12:AT+FCLASS=2\r]
Mar 22 11:30:00.31: [26497]: --> [2:OK]
Mar 22 11:30:00.31: [26497]: <-- [10:AT+FTBC=0\r]
Mar 22 11:30:00.42: [26497]: --> [2:OK]
Mar 22 11:30:00.42: [26497]: <-- [10:AT+FBOR=0\r]
Mar 22 11:30:00.53: [26497]: --> [2:OK]
Mar 22 11:30:00.53: [26497]: <-- [13:AT+FPHCTO=30\r]
Mar 22 11:30:00.64: [26497]: --> [2:OK]
Mar 22 11:30:00.64: [26497]: <-- [9:AT+FBUG=\r]
Mar 22 11:30:00.75: [26497]: --> [2:OK]
Mar 22 11:30:00.75: [26497]: <-- [24:AT+FDCC=1,5,2,2,0,0,0,0\r]
Mar 22 11:30:00.87: [26497]: --> [2:OK]
Mar 22 11:30:00.87: [26497]: <-- [25:AT+FLID="DELTASPED Kft."\r]
Mar 22 11:30:00.99: [26497]: --> [2:OK]
Mar 22 11:30:00.99: [26497]: DIAL 00039059525759
Mar 22 11:30:00.99: [26497]: <-- [19:ATDT00039059525759\r]
Mar 22 11:31:06.96: [26497]: --> [8:+FHNG: 1]
Mar 22 11:31:06.97: [26497]: REMOTE HANGUP: Ring detect without successful
handshake (code 1)
Mar 22 11:31:06.97: [26497]: SEND FAILED: Ring detect without successful
handshake
Mar 22 11:31:06.97: [26497]: <-- [5:ATH0\r]
Mar 22 11:31:08.78: [26497]: --> [2:OK]
Mar 22 11:31:08.79: [26497]: MODEM set DTR OFF
Mar 22 11:31:08.79: [26497]: STATE CHANGE: SENDING -> MODEMWAIT (timeout 5)
Mar 22 11:31:08.79: [26497]: SESSION END


My config:

FAXNumber:              +36.1.347.2020
LongDistancePrefix:     06
InternationalPrefix:    00
DialStringRules:        etc/dialrules.europe
ServerTracing:          0xFFFFF
SessionTracing:         0xFFFFF
TracingMask:            0x10
RecvFileMode:           0600
LogFileMode:            0600
DeviceMode:             0600
RingsBeforeAnswer:      1
SpeakerVolume:          off
GettyArgs:              "-h %l dx_%s"
LocalIdentifier:        "DELTASPED Kft."
TagLineFont:            etc/lutRS18.pcf
TagLineFormat:          "From %%l|%c|Page %%P of %%T"
MaxRecvPages:           25
ModemType:              Class2          # use class 2 interface
ModemRate:              38400
ModemFlowControl:       xonxoff         # default
ModemWaitForConnect:    yes             # wait for CONNECT on answer
#
#ModemResetCmds:        AT&F2           # what you want for a Supra
ModemNoFlowCmd:         ""              # disable flow control cmd
#ModemNoFlowCmd:        AT&K            # disable flow control cmd
ModemHardFlowCmd:       AT&K3           # hardware flow control cmd
ModemSoftFlowCmd:       AT&K4           # software flow control cmd
ModemSetupDTRCmd:       AT&D3           # DTR off causes modem to reset
ModemSetupDCDCmd:       AT&C1           # DCD follows carrier
ModemSetupAACmd:        AT+FCLASS=0;+FAA=1 # enable in class 0
#
ModemSendFillOrder:     LSB2MSB         # as expected
ModemRecvFillOrder:     MSB2LSB         # opposite of what makes sense
Class2RecvDataTrigger:  "\022"          # a la 2388-B
Class2DCCQueryCmd:      "!(0,1),(0-5),(0-4),(0-2),(0),(1),(0),(0-7)"
MaxConsecutiveBadLines: 0
PercentGoodLines:       0
#ModemHardFlowCmd:      ""              # string, command for setting
hardware flow control between DTE and DCE
#ModemNoFlowCmd:        ""              # string, command for disabling
hardware flow control between DTE and DCE
Class2BugCmd:           AT+FBUG=0

Imre.



____________________ HylaFAX(tm) Users Mailing List _______________________
 To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null



Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services