[hylafax-users] (cvs) RTN with 2-D, ok (MCF) with 1-D
Note: there's a difference in results between HylaFAX from April 2000,
and the latest cvs (20001022)
==================
RECEIVING SIDE:
- software: Win98+MSFax+MSExchange client
- modem-fax: Trust AE1414
SENDING SIDE:
- software: HylaFAX cvs 20001022
- modem-fax #1: Class1, Rockwell chipset
V2.083-K56_DLS / RCV56DPF L8570A Rev 47.22/47.22
- modem-fax #2: Class1, TOPIC chipset
TP560 Data/Fax/Voice 56K Modem
External Controller Ver1.20, CheckSum=2FF2 Date:Feb 17 18:35
DSP Ver1.10 CheckSum=7A64 Date:Feb 16 09:00
=====================
modem-fax #1 can send to the Trust with no problem whatsoever, both 1-D
and 2-D.
modem-fax #2 can send to the Trust with no problems only in 1-D;
2-D causes the following:
- RTN, ignored with RTNHandlingMethod
- The receiving side see the fax flagged as <Partially Received> in
MSExchange (the fax is fully received, though)
- The tiff file created on the receiving side has all the data, but from
below the last line of text to to the end of the page there's a
"barcode" effect.
Documents are 1 page only, postscript or ascii.
Fully reproducible, all fax-modems are "in house" so I can do all sort
of tests.
I know the problem may be the fax-modem #2, the point is that if I use
the same modem-fax on the same line to the same receiving fax using
MSFax, then the fax goes through ok (fully received, not <Partially
received>). I don't know if MSFax does 2-D, though.
Also, there are difference in behavior with HylaFAX beta2 (april 2000).
April 2000:
- sometimes it gets RTN, retries and is ok (so the fax completes ok in 1
call and 2 tries in the same call); sometimes it goes through ok with 1
try in 1 call.
- if I place the call at 12000bps then it goes ok with 1 call and 1 try.
Oct 2000:
-always gets RTN and does not complete the call succesfully (unless I
use RTNHandlingMethod).
The config file used is the same (normal config for class1)
Fax-modem #2 can succesfully use 2-D with another fax machine.
I searched for a firmware upgrade for the "topic" chipset, but found
nothing.
======== 2-D
Oct 23 18:11:41.33: [ 2892]: SENT 24305 bytes of data
Oct 23 18:11:41.33: [ 2892]: SEND 2D RTC
Oct 23 18:11:41.33: [ 2892]: <-- data [30]
Oct 23 18:11:41.33: [ 2892]: <-- data [2]
Oct 23 18:11:41.33: [ 2892]: SEND end page
Oct 23 18:11:43.64: [ 2892]: --> [2:OK]
Oct 23 18:11:43.64: [ 2892]: MODEM set XON/XOFF/DRAIN: input ignored,
output disabled
Oct 23 18:11:43.64: [ 2892]: DELAY 95 ms
Oct 23 18:11:43.74: [ 2892]: SEND send EOP (no more pages or documents)
Oct 23 18:11:43.74: [ 2892]: <-- [9:AT+FTH=3\r]
Oct 23 18:11:43.79: [ 2892]: --> [7:CONNECT]
Oct 23 18:11:43.79: [ 2892]: <-- HDLC<3:FF C8 F4>
Oct 23 18:11:43.79: [ 2892]: <-- data [3]
Oct 23 18:11:43.79: [ 2892]: <-- data [2]
Oct 23 18:11:45.11: [ 2892]: --> [1:^Q]
Oct 23 18:11:45.11: [ 2892]: --> [2:OK]
Oct 23 18:11:45.11: [ 2892]: <-- [9:AT+FRH=3\r]
Oct 23 18:11:45.44: [ 2892]: --> [7:CONNECT]
Oct 23 18:11:46.53: [ 2892]: --> HDLC<5:FF C8 32 75 EC>
Oct 23 18:11:46.54: [ 2892]: --> [2:OK]
Oct 23 18:11:46.54: [ 2892]: SEND recv RTN (retrain negative)
Oct 23 18:11:46.54: [ 2892]: SEND FAX (00000024): FROM go@i4 TO
0,01234567890 (pag
==== 1-D
Oct 23 18:12:58.43: [ 2906]: SENT 33774 bytes of data
Oct 23 18:12:58.43: [ 2906]: SEND 1D RTC
Oct 23 18:12:58.43: [ 2906]: <-- data [29]
Oct 23 18:12:58.43: [ 2906]: <-- data [2]
Oct 23 18:12:58.43: [ 2906]: SEND end page
Oct 23 18:13:01.10: [ 2906]: --> [2:OK]
Oct 23 18:13:01.10: [ 2906]: MODEM set XON/XOFF/DRAIN: input ignored,
output disabled
Oct 23 18:13:01.10: [ 2906]: DELAY 95 ms
Oct 23 18:13:01.20: [ 2906]: SEND send EOP (no more pages or documents)
Oct 23 18:13:01.20: [ 2906]: <-- [9:AT+FTH=3\r]
Oct 23 18:13:01.25: [ 2906]: --> [7:CONNECT]
Oct 23 18:13:01.25: [ 2906]: <-- HDLC<3:FF C8 F4>
Oct 23 18:13:01.25: [ 2906]: <-- data [3]
Oct 23 18:13:01.25: [ 2906]: <-- data [2]
Oct 23 18:13:02.57: [ 2906]: --> [1:^Q]
Oct 23 18:13:02.57: [ 2906]: --> [2:OK]
Oct 23 18:13:02.57: [ 2906]: <-- [9:AT+FRH=3\r]
Oct 23 18:13:02.90: [ 2906]: --> [7:CONNECT]
Oct 23 18:13:03.99: [ 2906]: --> HDLC<5:FF C8 31 45 8F>
Oct 23 18:13:04.00: [ 2906]: --> [2:OK]
Oct 23 18:13:04.00: [ 2906]: SEND recv MCF (message confirmation)
Oct 23 18:13:04.00: [ 2906]: SEND FAX (00000025): FROM go@i4 TO
0,01234567890 (pa
Any suggestion (ie.: where to get firmware, if the topic chipset has
upgradable firmware) is appreciated.
--