Hylafax Mailing List Archives

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

[hylafax-users] 3Com modem wedged



Hi.
I'm using Hylafax last version on a Linux Mandrake 1.0 corporate.
I have 3 modems 3Com 56K Professional Message connected to the server for
inbound and outbound faxes.
Sometimes I receive a message "the modem on ttyS0 (or ttyS3) appears to be
wedged".
Here is the log:
Oct 23 11:28:02.03: [13070]: SESSION BEGIN 00000185 390532820896
Oct 23 11:28:02.03: [13070]: <-- [4:ATA\r]
Oct 23 11:28:55.46: [13070]: --> [10:NO CARRIER]
Oct 23 11:28:55.46: [13070]: ANSWER: Ring detected without successful
handshake
Oct 23 11:28:55.46: [13070]: SESSION END

Someone knows how to solve it ?

I'm using this type of modem in Class 2.0 with the following config.ttyS0
# $Id: class2.0,v 1.12 1996/06/24 02:58:33 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names
of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
PageChop: none
#
# Generic Class 2.0 modem configuration.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode:  39
AreaCode:  0532
FAXNumber:  +390532820894
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing:  1
SessionTracing:  11
RecvFileMode:  0600
LogFileMode:  0600
DeviceMode:  0600
RingsBeforeAnswer: 1
SpeakerVolume:  off
GettyArgs:  "-h %l dx_%s"
LocalIdentifier: "Weitek FaxServer"
TagLineFont:  etc/lutRS18.pcf
TagLineFormat:  "From %%l|%c|Page %%p of %%t"
MaxRecvPages:  25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:  Class2.0 # use class 2.0 interface
ModemRate:  38400  # DCE-DTE communication rate
ModemFlowControl: rtscts  # XON/XOFF flow control assumed
#
ModemNoFlowCmd:  AT&H0&I0&R1 # setup modem for no flow control
ModemHardFlowCmd: AT&H1&I0&R2 # setup modem for hardware flow control
ModemSoftFlowCmd: AT&H2&I2&R1 # setup modem for software flow control
#
ModemSetupDTRCmd: ATS13=1&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1  # setup so DCD reflects carrier (or not)
ModemResultCodesCmd: ATQ0X4  # enable extended result codes
#
# NB: adaptive answer only seems to work properly when
#     the modem is left idling in Class 2.0
#
ModemSetupAACmd: AT+FAA=1
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
ModemSetVolumeCmd: "ATM0 ATM1 ATM1 ATM1 ATM1"
#
# Modem does not support HDLC frame tracing; we add this just
# to eliminate spurious ERROR results that confuse the naive.
#
Class2BUGCmd:  AT+FBU=0
#
# The modem doesn't support copy quality checking, even though it
# returns (0-2,0-2) for AT+FCQ=?; therefore we disable it to keep
# the fax software from complaining.
#
Class2CQCmd:  AT+FCQ=0,0
Class2CQQueryCmd: !(0),(0) # override modem response
#
# Disables the reporting of bad frames by the modem.  This
# overcomes a firmware problem in the x2 and V90 Sportsters.
# It is not necessary for the Courier modem.
#
Class2NRCmd:    AT+FNR=1,1,1,0
#
# Settaggi per WEITEK
#
ModemDialCmd: ATDT0%s
ModemWaitTimeCmd: ATS7=90
ModemResetCmds: AT+MCA=0  #disabilita segreteria
Class2SendRTC: yes
Class2Cmd: AT+FCLASS=2.0  #command to enter in class 2.0
Class2BORCmd: AT+FBO=0  #bit order for phase B/C/D (direct)
Class2AbortCmd: AT+FSK   #abort session command
Class2DCCQueryCmd: AT+FCC=? #query for modem capabilities
Class2TBCCmd: AT+FPP=0  #setup stream mode
Class2CRCmd: AT+FCR=1  #enable capability to receive
Class2PHCTOCmd: AT+FCT=30  #set phase C timeout parameter


Someone has the right config.ttyS0 for my type of modem ?

Thanks in advance for any answer



-------------------------
Otello Artosi
WEITEK - AETNA Group
E-mail: otello@weitek.it
PGP fp: E2C3 98DF A79F 401D 0775  1CFF E2A4 E581 82E5 F713



____________________ HylaFAX(tm) Users Mailing List _______________________
 To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null



Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services