Hello,
(first sorry for my very bad english, I will do my very best.)
I use SuSE6.4 with:
hylafax-4.1beta2-135 tiff-3.4-0 libtiff-3.4.final-0
My modem:
Elsa Mikrolink 28.8TQV.
The problem is that i can only send and recieve the top of the page,
that means I get only the tagline (or the half of it) or hhe tagline
with zero or 1 or 2 lines, nothing more. Here is a log:
---schnipp---
Jul 19 14:09:10.75: [ 8644]: SESSION BEGIN 00000015 4989244xxxx26
Jul 19 14:09:10.75: [ 8644]: SEND FAX: JOB 11 DEST 089244xxxx26 COMMID
00000015
Jul 19 14:09:10.75: [ 8644]: DELAY 2600 ms
Jul 19 14:09:13.35: [ 8644]: <-- [14:ATE0V1Q0S0=0H\r]
Jul 19 14:09:13.36: [ 8644]: --> [2:OK]
Jul 19 14:09:13.36: [ 8644]: <-- [21:ATS8=2S7=60\Q3&D2&C1\r]
Jul 19 14:09:13.37: [ 8644]: --> [2:OK]
Jul 19 14:09:13.37: [ 8644]: <-- [14:AT+FCLASS=2.0\r]
Jul 19 14:09:13.38: [ 8644]: --> [2:OK]
Jul 19 14:09:13.38: [ 8644]: <-- [9:AT+FLO=2\r]
Jul 19 14:09:13.39: [ 8644]: --> [2:OK]
Jul 19 14:09:13.39: [ 8644]: <-- [9:AT+FPP=0\r]
Jul 19 14:09:13.40: [ 8644]: --> [2:OK]
Jul 19 14:09:13.40: [ 8644]: <-- [9:AT+FBO=0\r]
Jul 19 14:09:13.41: [ 8644]: --> [2:OK]
Jul 19 14:09:13.41: [ 8644]: <-- [10:AT+FCT=30\r]
Jul 19 14:09:13.42: [ 8644]: --> [2:OK]
Jul 19 14:09:13.42: [ 8644]: <-- [15:AT+FNR=1,1,1,1\r]
Jul 19 14:09:13.43: [ 8644]: --> [2:OK]
Jul 19 14:09:13.43: [ 8644]: <-- [9:AT+FIE=0\r]
Jul 19 14:09:13.44: [ 8644]: --> [2:OK]
Jul 19 14:09:13.44: [ 8644]: <-- [23:AT+FCC=1,5,2,2,0,0,0,0\r]
Jul 19 14:09:13.45: [ 8644]: --> [2:OK]
Jul 19 14:09:13.45: [ 8644]: <-- [7:ATL2M1\r]
Jul 19 14:09:13.46: [ 8644]: --> [2:OK]
Jul 19 14:09:13.46: [ 8644]: <-- [14:AT+FCLASS=2.0\r]
Jul 19 14:09:13.57: [ 8644]: --> [2:OK]
Jul 19 14:09:13.57: [ 8644]: <-- [9:AT+FLO=2\r]
Jul 19 14:09:13.68: [ 8644]: --> [2:OK]
Jul 19 14:09:13.68: [ 8644]: <-- [9:AT+FPP=0\r]
Jul 19 14:09:13.79: [ 8644]: --> [2:OK]
Jul 19 14:09:13.79: [ 8644]: <-- [9:AT+FBO=0\r]
Jul 19 14:09:13.90: [ 8644]: --> [2:OK]
Jul 19 14:09:13.90: [ 8644]: <-- [10:AT+FCT=30\r]
Jul 19 14:09:14.01: [ 8644]: --> [2:OK]
Jul 19 14:09:14.01: [ 8644]: <-- [15:AT+FNR=1,1,1,1\r]
Jul 19 14:09:14.12: [ 8644]: --> [2:OK]
Jul 19 14:09:14.12: [ 8644]: <-- [9:AT+FIE=0\r]
Jul 19 14:09:14.23: [ 8644]: --> [2:OK]
Jul 19 14:09:14.23: [ 8644]: <-- [23:AT+FCC=1,5,2,2,0,0,0,0\r]
Jul 19 14:09:14.34: [ 8644]: --> [2:OK]
Jul 19 14:09:14.34: [ 8644]: <-- [24:AT+FLI="Robert W. Kuhn"\r]
Jul 19 14:09:14.46: [ 8644]: --> [2:OK]
Jul 19 14:09:14.46: [ 8644]: DIAL 089244xxxx26
Jul 19 14:09:14.46: [ 8644]: <-- [17:ATDT089244xxxx26\r]
Jul 19 14:09:26.80: [ 8644]: --> [4:+FCO]
Jul 19 14:09:28.65: [ 8644]: --> [27:+FCI:" FAX2MAIL GATEWAY"]
Jul 19 14:09:28.65: [ 8644]: REMOTE CSI "FAX2MAIL
GATEWAY"
Jul 19 14:09:28.65: [ 8644]: REMOTE CSI "FAX2MAIL GATEWAY"
Jul 19 14:09:28.65: [ 8644]: --> [20:+FIS:1,5,0,2,1,1,0,0]
Jul 19 14:09:28.65: [ 8644]: --> [2:OK]
Jul 19 14:09:28.65: [ 8644]: REMOTE best rate 14400 bit/s
Jul 19 14:09:28.65: [ 8644]: REMOTE max page width 1728 pixels in 215 mm
Jul 19 14:09:28.65: [ 8644]: REMOTE max unlimited page length
Jul 19 14:09:28.65: [ 8644]: REMOTE best vres 7.7 line/mm
Jul 19 14:09:28.65: [ 8644]: REMOTE best format 2-D MR
Jul 19 14:09:28.65: [ 8644]: REMOTE supports T.30 Annex A, ECM
Jul 19 14:09:28.65: [ 8644]: REMOTE best 0 ms/scanline
Jul 19 14:09:28.65: [ 8644]: USE 14400 bit/s
Jul 19 14:09:28.65: [ 8644]: USE 0 ms/scanline
Jul 19 14:09:28.65: [ 8644]: SEND file "docq/doc11.ps;01"
Jul 19 14:09:28.65: [ 8644]: USE page width 1728 pixels in 215 mm
Jul 19 14:09:28.65: [ 8644]: USE unlimited page length
Jul 19 14:09:28.65: [ 8644]: USE 7.7 line/mm
Jul 19 14:09:28.65: [ 8644]: USE 1-D MR
Jul 19 14:09:28.65: [ 8644]: <-- [23:AT+FIS=1,5,0,2,0,0,0,0\r]
Jul 19 14:09:28.76: [ 8644]: --> [2:OK]
Jul 19 14:09:28.76: [ 8644]: <-- [7:AT+FDT\r]
Jul 19 14:09:35.81: [ 8644]: --> [20:+FCS:1,5,0,2,0,0,0,0]
Jul 19 14:09:36.12: [ 8644]: --> [7:CONNECT]
Jul 19 14:09:36.12: [ 8644]: SEND begin page
Jul 19 14:09:36.12: [ 8644]: <-- data [1027]
Jul 19 14:09:36.12: [ 8644]: <-- data [1027]
Jul 19 14:09:36.12: [ 8644]: <-- data [1030]
Jul 19 14:09:36.12: [ 8644]: <-- data [1033]
Jul 19 14:09:36.49: [ 8644]: <-- data [963]
Jul 19 14:09:36.84: [ 8644]: SENT 5056 bytes of data
Jul 19 14:09:36.84: [ 8644]: SEND 1D RTC
Jul 19 14:09:36.84: [ 8644]: <-- data [9]
Jul 19 14:09:36.84: [ 8644]: SEND end page
Jul 19 14:09:36.84: [ 8644]: SEND send EOP (no more pages or documents)
Jul 19 14:09:36.84: [ 8644]: <-- data [2]
Jul 19 14:09:43.93: [ 8644]: --> [7:+FHS:00]
Jul 19 14:09:43.93: [ 8644]: REMOTE HANGUP: Normal and proper end of
connection
Jul 19 14:09:43.93: [ 8644]: SEND recv MCF (message confirmation)
Jul 19 14:09:43.93: [ 8644]: SEND FAX (00000015): FROM
root@maschine.vermtech.de
Jul 19 14:09:43.93: [ 8644]: SEND FAX (00000015): FROM
root@maschine.vermtech.de
Jul 19 14:09:43.93: [ 8644]: <-- [4:ATH\r]
Jul 19 14:09:45.14: [ 8644]: --> [2:OK]
Jul 19 14:09:45.14: [ 8644]: SESSION
END
---scnapp---
Here is my config.modem:
---schnipp---
#
# Class 2.0 modem configuration for ELSA 33.6 TQV.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode: 49
AreaCode: 331
FAXNumber: +49.331.9xxxx41
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing: 1
SessionTracing: 11
RecvFileMode: 0644
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 1
SpeakerVolume: off
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "Robert W. Kuhn"
LogFacility: local7
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "Von %%l|%c|Seite %%p von %%t"
PercentGoodLines: 80
MaxConsecutiveBadLines: 20
MaxRecvPages: 250
ModemPriority: 200
#
ModemType: Class2.0 # use this to supply a hint
ModemRate: 115200 # max rate for DCE-DTE
communication
ModemFlowControl: rtscts # XON/XOFF flow control assumed
ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier
(or not)
#
ModemDialCmd: ATDT%s
#
# Other possible configuration stuff. The default strings are
# shown below. Only those that are different from the defaults
# need to be included in the configuration file.
#
ModemAnswerCmd: ATA # use this to answer phone
ModemNoFlowCmd: AT\Q0
ModemHardFlowCmd: AT\Q3
ModemSoftFlowCmd: AT\Q1
ModemNoAutoAnswerCmd: ATS0=0 # disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
ModemEchoOffCmd: ATE0 # disable command echo
ModemVerboseResultsCmd: ATV1 # enable verbose command results
ModemResultCodesCmd: ATQ0 # enable result codes
ModemOnHookCmd: ATH # place phone on hook (hangup)
ModemSoftResetCmd: ATZ # do soft reset of modem
ModemWaitTimeCmd: ATS7=60 # wait 60 seconds for carrier
ModemCommaPauseTimeCmd: ATS8=2 # comma pause time is 2 seconds
ModemRecvFillOrder: LSB2MSB # bit order of received
facsimile
ModemSendFillOrder: LSB2MSB # bit order modem expects for
transmit
#
# Configuration parameters for Class 2.0 modems.
#
Class2Cmd: AT+FCLASS=2.0 # command to enter class 2.0
Class2BORCmd: AT+FBO=0 # bit order for phase B/C/D
(direct)
Class2CQCmd: "" # commands to enable copy
quality proc.
Class2AbortCmd: AT+FKS # abort session command
Class2CQQueryCmd: AT+FCQ=? # query for copy quality
capabilities
Class2DCCQueryCmd: AT+FCC=? # query for modem capabilities
Class2TBCCmd: AT+FPP=0 # setup stream mode
Class2CRCmd: AT+FCR=1 # enable capability to receive
Class2PHCTOCmd: AT+FCT=30 # set phase C timeout parameter
Class2BUGCmd: AT+FBU=1 # enable HDLC frame tracing
Class2LIDCmd: AT+FLI # set local identifier command
Class2DCCCmd: AT+FCC # set modem capabilities command
Class2DISCmd: AT+FIS # set session parameters command
Class2DDISCmd: "" # disable pre-dial DIS command
hack
Class2CIGCmd: AT+FPI # set polling identifier command
Class2NRCmd: AT+FNR=1,1,1,1 # setup status reporting command
Class2PIECmd: AT+FIE=0 # disable interrupt-enable
command
Class2PTSCmd: AT+FPS # set post-page status command
Class2SPLCmd: AT+FSP # set polling indicator command
Class2NFLOCmd: AT+FLO=0 # set no flow control command
Class2SFLOCmd: AT+FLO=1 # set software flow control
command
Class2HFLOCmd: AT+FLO=2 # set hardware flow control
command
---schnapp---
Thank you very much -
Robert.