Hylafax Mailing List Archives

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: Missing EOL



> I checked the thread and saw that this "Missing EOL' is actually a bug.
> I downloaded the protocol-rtn.patch by Dimtry Bely created on 29 Mar 00

Your problem is a misconfiguration, not a bug.
> 
> I ran:-
> patch -bp0 --verbose <protocol-rtn.patch (on the root of my hylafax 4.1beta2)

This would be more correctly called the RTC patch; RTN is a symptom that
can be associated with duplicate RTCs, but the actual patch suppresses
duplicate RTCs.

> May 20 00:28:51.38: [ 3823]: RECV: begin page
> May 20 00:28:51.38: [ 3823]: RECV: send trigger 021
> May 20 00:31:04.67: [ 3823]: RECV: Missing EOL after 5 seconds
> May 20 00:31:04.67: [ 3823]: REMOTE HANGUP: Missing EOL after 5 seconds 
> (section 3.2/T.4) (code 91)

This happens if the trigger is wrong.  Many modems need 022.  The RTC 
problem only occurs on transmission and only at the end of the page;
this happened on reception and at the beginning of the page.