Re: Strange problem : modem capabilities not reported to fax machines



Andrea Albarelli <andrea@side7.it> writes:

> Hi, I have got the following strange problem :
> 
> I have an Hylafax 4.1beta2 on Linux 2.2.14 with a Zyxel 2864i
> I forced in config.ttyS0 the capabilities of my modem with :
> 
> Class2DCCQueryCmd:      "!(0-1),(0-5),(0-2),(0-2),(0-1),(0-1),(0),(0-7)"
> 
> So far so good, please note the ECM ( error correction mode ) capability
> enabled.

Zyxel Elite does *not* support ECM in Class 2.0 (as well as U1496). Why did
you decide it had to? You could "enable" ECM only if you wrote new firmware
:-) BTW, I recommend you not to change parameters, whose meaning is not
clear enough for you.

Hope to hear from you soon,
Dmitry