Re: Multi-Tech MT3334ZDX modem question



Alan Hanson wrote:
> 
> HylaFAX 4.0pl2 version
> Solaris 2.7 server
> 
> We have purchased a couple of new Multi-Tech MT3334ZDX modems for
> out-going fax.  I can not get these modems to send the data out.  It
> dials up the other modem and immediately disconnects when the called
> modem comes online (1/2 sec).  The "faxstat -s" indicates that there is
> no response from the called fax.
> 
> I have an older Multi-Tech MT2834ZDX modem that worked immediately on
> setup.
> 
> In using the "faxaddmodem" routine, I have accepted the default values
> and I have attempted to customize the settings and nothing works for me
> on these new modems.
> 
> I have attempted to check the settings between the old and new modems
> using the AT&V command and all the settings that display are identical.
> Not all the setting show up though.  How can I see all the settings, for
> example all the Sn settings?
> 
> Thanks in advance.
> Alan Hanson

Hi Alan,

did you already try to use the old config-files for your new modems.

The only way I know to get the register content is with
ATSn=?

I attach the config-files, I use for outbound service with MultiTech
Modems.

I think fort the ZDX Modems you have to change the folling params:
(only relevant on outbound service)
ModemHardFlowCmd:       AT&K3           # hardware flow control cmd
ModemSoftFlowCmd:       AT&K4           # software flow control cmd
ModemSetupAACmd: AT+FAA=1+FCLASS=0      # leave in data class for answer
ModemRecvFillOrder:     MSB2LSB         # opposite of what makes sense

Hope it helps
Matthias

-- 
HAGOS eG                 phone: +49 711 7880592
Matthias Reich             fax: +49 711 7880599
Industriestr. 62           web: http://www.hagos.de
D-70565 Stuttgart         mail: rei@hagos.de
Germany
# $Id: class2,v 1.23 1996/06/24 02:58:32 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
# 
# Permission to use, copy, modify, distribute, and sell this software and 
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
# 
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
# 
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
# OF THIS SOFTWARE.
#

#
# Generic Class 2 modem configuration.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode:		49
AreaCode:		711
FAXNumber:		+49.711.7880549
LongDistancePrefix:	0
InternationalPrefix:	00
DialStringRules:	etc/dialrules
ServerTracing:		0x00040
SessionTracing:		11
RecvFileMode:		0600
LogFileMode:		0600
DeviceMode:		0600
RingsBeforeAnswer:	0
SpeakerVolume:		high
GettyArgs:		"-h %l dx_%s"
LocalIdentifier:	"HAGOS eG Stuttgart"
TagLineFont:		etc/lutRS18.pcf
TagLineFormat:		"Von %%l|%c|Seite %%p von %%t"
QualifyTSI:		etc/tsi
PercentGoodLines:	90
MaxConsecutiveBadLines:	10
MaxRecvPages:		25
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:		Class2		# use class 2 interface
ModemRate:		38400		# lock rate for DCE-DTE communication
ModemFlowControl:	rtscts		# default
#
ModemResetCmds:		AT&FX3
ModemHardFlowCmd:	AT&E4		# hardware flow control
ModemSoftFlowCmd:	AT&E5		# software flow control
ModemSetupDTRCmd:	AT&D3		# setup so DTR drop resets modem
ModemSetupDCDCmd:	AT&C1		# setup so DCD reflects carrier (or not)
ModemSetupAACmd:	AT+FAA=1	# enable adaptive-answer in class 2
#
# NB: some models get confused by the @
#
ModemDialCmd:		ATDT0,01030%s
#
Class2RecvDataTrigger:	"\022"		# character sent to modem to start recv
#


Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services