On Thu, 8 Jul 1999, Matthias Reich EDV-Programmierung wrote:
> Hello again Hyla-freaks !!
>
> I tried to set up a USR Sportster X2 Flash for Hylafax
> the result is in the following session tracing:
>
> has anyone an idea what is wrong ??
>
> I use Hylafax V4.0pl1
> Solaris 2.5.1
First, switch to v4.0pl2 or the new beta release: 4.0pl1 has been
out of date for a while. There were also some serious security
issues with it (the CGI scripts were quite dangerous!)
> Jul 08 16:10:40.99: [15324]: <-- [14:AT+FCLASS=2.0\r]
> Jul 08 16:10:41.21: [15324]: --> [2:OK]
And this may be your problem: try running it as Class 1 or Class 2,
whichever it will support according to the "probemodem" command. Class
2.0 has never had good reports from other users that I've seen.
Nico Kadel-Garcia
Senior Engineer, CIRL
Mass. Eye and Ear Infirmary
raoul@cirl.meei.harvard.edu