Re: Normal and proper end of connection



Hi Karl,


> Jun 06 21:32:44.17: [ 1660]: RECV: 241 bytes of data, 29 total lines
> Jun 06 21:32:44.17: [ 1660]: --> [16:+FPS:2,7F,5F,0,0]
> Jun 06 21:32:45.33: [ 1660]: --> [6:+FET:2]
> Jun 06 21:32:45.33: [ 1660]: RECV recv EOP (no more pages or documents)
> Jun 06 21:32:45.33: [ 1660]: --> [5:ERROR]
> Jun 06 21:32:45.33: [ 1660]: MODEM Command error
> Jun 06 21:32:45.33: [ 1660]: RECV send RTN (retrain negative)
                                        ^^^^^^^^^^^^^^^^^^^^^^^^
See the documentation for the retrain negative error.

> 
> #
> # Modem-related stuff: should reflect modem command interface
> # and hardware connection/cabling (e.g. flow control).
> #
> ModemType:              Class2.0        # use this to supply a hint
> ModemRate:              115200          # max rate for DCE-DTE
                        ^^^^^^^^^^
Try 19200.

> communication
> ModemFlowControl:       rtscts          # XON/XOFF flow control assumed
                        ^^^^^^^^^^
Try xonxoff.

Hope this helps.