Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
Zyxel U-1496E RTN errors
I just installed Hylafax v4.0pl2, and am using it with a Zyxel U-1496E
V6.19 fax modem.
I found that we were getting quite a few RTN (retrain negative) errors
when using this modem in Class 2.0 mode.
In some cases the receiving fax machine was in our own location, so
line errors are unlikely. I installed the Hylafax tag line patch to
eliminate that bug as a potential cause but the problem continued.
I found that using the modem in Class 2 (rather than Class 2.0) mode
has eliminated this problem. We have now sent several hundred faxes
in Class 2 mode with only one RTN error failure. The logs show that in
Class 2 mode there is an extra handshaking step at the end of a page
which is not present in Class 2.0 mode. Perhaps this extra step
avoids some timing problem present in the Zyxel Class 2.0 firmware.
I found other reports of the RTN problem in the mailing list archive,
but no reported solution. Perhaps the information on the Hylafax web
site about the Zyxel U-1496E should be updated to suggest using Class 2
mode with this modem.