Hylafax Mailing List Archives

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: Wierd Flowcontrol problem during fax recv



-----BEGIN PGP SIGNED MESSAGE-----

On Thu, 3 Sep 1998, Anthony Rumble wrote:

> I have the flow in the config set to :-
> 
> ModemFlowControl:      rtscts
> 
> Yet.. in fax receive.. it still turns on XON/XOFF flowcontrol.. and turns
> off CRTSCTS in the stty modems for the terminal!

Umm: it would help to say the brand of modem, your version of HylaFAX,
your computer type, etc.

For example, a number of modem configuration files over-write certain
default Class 1 or Class 2 values for default behavior, for various
reasons. It's very difficult to diagnose or give good hints without
the configuration information.

At least some modems also only cope with xon/xoff for FAX use, for example
the PPI 14400 FXMT, with the following field set.

	ModemAnswerFaxBeginCmd:	"<19200><xon>"	# modem switches on fax receive


			Nico Kadel-Garcia
			Senior Engineer, CIRL 
			Mass. Eye and Ear Infirmary
			raoul@cirl.meei.harvard.edu

-----BEGIN PGP SIGNATURE-----
Version: 2.6.2

iQCVAwUBNe7FTj/+ItycgIJRAQGpAQP/dNA9Dm/HF3GFqDFEfjdkiWSVYNCCRRX6
zmSZ5NxFW3Hjfb1fi5SEJMoWTz64gqHPkDpJsitTY2xTVC7bQ/bZQo0+JgAaiJdI
DtcRmRcF1Q0RxaRbp/E65jC1+zSaRT+1XYOZUE3p6t7oHLNjn4P+wIXONkGy6v76
GNnFa7FArnI=
=87/d
-----END PGP SIGNATURE-----



Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services