Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
Re: Unspecified Transmit Phase B error
At 19:07 16/10/1997 -0700, John Hazard wrote:
>I guees I'll answer my own question the following line in
>cuaa0/config:
>
>
>
>Class2NRCmd: AT+FNR=1,1,1,0 # setup status reporting command
>
>
>JH
>
This fix was also suggested by, I believe, Dave Wreski; but unfortunately
in neither case was the actual model of the US Robotics modem actually
mentioned.
Could you let us know?
HylaFAX puts the relevant info in the syslog/messages - for instance mine
says :-
MODEM USROBOTICS SPORTSTER 28800 FAX
Product Type UK External
Options V32bis, V.FC, V.34
Fax Options Class 1 / Class 2.0
Clock Freq 20.16 MHz
Eprom 256K
Ram 32K
Supervisor Date 04/28/95
DSP Date 03/31/95
Supervisor rev 044-6.0
DSP rev 11.3
which, touch wood, works perfectly in a send-only environment.
Zdravko Balorda on the 29 May 97 mentioned that, in his opinion,
anything newer than this :
Supervisor date 04/18/95
DSP date 03/31/95
Supervisor rev 6.0.5
DSP rev 1.0.9
had problems in Class 2.0 mode. (Perhaps mine just snuck through).
Thanks,
Phil Watkinson,
Boston, UK.