Re: HylaFAX vs USR Courier I modem
At 23:01 Uhr +0200 11.05.1997, <jonc@pinnacle.co.nz> wrote:
> On Sat, 10 May 1997, Ingo Ciechowski wrote:
>
> [snip]
> > If someone knows why that "SEND FAILED" message is showing up in the log
> > I'd really be glad to be told ;-)
> >
> [snip]
>
> > May 10 11:49:43.77: [ 8102]: DIAL 333
> > May 10 11:49:43.77: [ 8102]: <-- [8:ATDT333\r]
> > May 10 11:49:57.96: [ 8102]: --> [7:ATDT333]
> > May 10 11:49:57.96: [ 8102]: SEND FAILED: Unknown problem (check modem
>power)
>
> Are you sure you provided the right number? I don't think there are
> too many places in the developed world that only have 3-number
> telephone numbers. Check out your dialrules file for unexpected number
> translation.
The destination number 333 is perfectly right since I'm trying this from
inside a larger PBX system and 333 is our real fax machine's internal
number -- and the fax machine is answering that call ;-)
However - HylaFAX is hanging up right after that :-{{
Ingo