Hi Lee,

Yes, that's exactly what I mean: I turned off the receiver machine in the middle of a fax. Here's a session log. Note especially what happened at 17:25:34.21 and at 17:49:02.86: At these 2 moments, the modem was totally stuck and didn't answer any more, so I tried to talk to it via minicom. When I launched minicom, in the first case, I saw the <timeout> messages appear in the logs, but minicom didn't display the usual AT/OK conversation. But I think that attempting to send this AT, or just trying to access the device did the trick. Even more funny: I really wanted to see a SESSION END in my logs, because that's what I'm expecting for a session to end clean. But it still wouldn't appear. So I launched minicom again, but unlike the first time, it didn't actually launch (crashed?); but the effect was that the SESSION END appeared in the logs. After that, if I opened minicom, everything was back to normal with the AT/OK conversation, so I knew now hell is over :)

Erich

Nov 29 16:56:42.80: [16366]: SESSION BEGIN 000000026 41313368198
Nov 29 16:56:42.80: [16366]: HylaFAX (tm) Version 4.2.0
Nov 29 16:56:42.80: [16366]: SEND FAX: JOB 12 DEST 0313368198 COMMID 000000026 DEVICE '/dev/ttyS0'
Nov 29 16:56:42.80: [16366]: <-- [9:AT+FLO=1\r]
Nov 29 16:56:42.95: [16366]: --> [2:OK]
Nov 29 16:56:42.95: [16366]: <-- [9:AT+FPP=0\r]
Nov 29 16:56:43.10: [16366]: --> [2:OK]
Nov 29 16:56:43.10: [16366]: <-- [9:AT+FBO=0\r]
Nov 29 16:56:43.24: [16366]: --> [2:OK]
Nov 29 16:56:43.24: [16366]: <-- [10:AT+FCT=30\r]
Nov 29 16:56:43.39: [16366]: --> [2:OK]
Nov 29 16:56:43.39: [16366]: <-- [15:AT+FNR=1,1,1,1\r]
Nov 29 16:56:43.54: [16366]: --> [2:OK]
Nov 29 16:56:43.54: [16366]: <-- [9:AT+FIE=0\r]
Nov 29 16:56:43.68: [16366]: --> [2:OK]
Nov 29 16:56:43.68: [16366]: <-- [23:AT+FCC=1,5,2,2,0,0,0,0\r]
Nov 29 16:56:43.84: [16366]: --> [2:OK]
Nov 29 16:56:43.84: [16366]: DIAL 5551234567
Nov 29 16:56:43.84: [16366]: <-- [15:ATDT5551234567\r]
Nov 29 16:56:58.58: [16366]: --> [4:+FCO]
Nov 29 16:57:01.50: [16366]: --> [119:+FNF: 00 00 11 80 00 80 49 10 53 41 49 4E 54 2D 47 4F 42 41 49 4E 20 20 20 20 00 5B 00 80 80 C0 07 02 01 00 01 01 01 01]

Nov 29 16:57:01.50: [16366]: REMOTE NSF " 00 00 11 80 00 80 49 10 53 41 49 4E 54 2D 47 4F 42 41 49 4E 20 20 20 20 00 5B 00 80 80 C0 07 02 01 00 01 01 01 01"

Nov 29 16:57:01.50: [16366]: NSF remote fax equipment: Canon Fax B100
Nov 29 16:57:01.50: [16366]: NSF remote station ID: "SAINT-GOBAIN    "
Nov 29 16:57:01.63: [16366]: --> [27:+FCI:"    +41 31 336 81 98"]
Nov 29 16:57:01.63: [16366]: REMOTE CSI "+41 555-123-4567"
Nov 29 16:57:01.63: [16366]: --> [20:+FIS:1,3,0,2,1,1,0,5]
Nov 29 16:57:01.63: [16366]: --> [2:OK]
Nov 29 16:57:01.63: [16366]: REMOTE best rate 9600 bit/s
Nov 29 16:57:01.63: [16366]: REMOTE max A4 page width (215 mm)
Nov 29 16:57:01.63: [16366]: REMOTE max unlimited page length
Nov 29 16:57:01.63: [16366]: REMOTE best vres 7.7 line/mm
Nov 29 16:57:01.63: [16366]: REMOTE best format 2-D MR
Nov 29 16:57:01.63: [16366]: REMOTE supports T.30 Annex A, 256-byte ECM
Nov 29 16:57:01.63: [16366]: REMOTE best 20 ms/scanline
Nov 29 16:57:01.63: [16366]: USE 9600 bit/s
Nov 29 16:57:01.63: [16366]: USE 20 ms/scanline
Nov 29 16:57:01.63: [16366]: SEND file "docq/doc13.ps;01"
Nov 29 16:57:01.63: [16366]: USE A4 page width (215 mm)
Nov 29 16:57:01.63: [16366]: USE unlimited page length
Nov 29 16:57:01.63: [16366]: USE 7.7 line/mm
Nov 29 16:57:01.63: [16366]: USE 1-D MH
Nov 29 16:57:01.63: [16366]: <-- [23:AT+FIS=1,3,0,2,0,0,0,5\r]
Nov 29 16:57:01.77: [16366]: --> [2:OK]
Nov 29 16:57:01.77: [16366]: <-- [7:AT+FDT\r]
Nov 29 16:57:07.35: [16366]: --> [20:+FCS:1,3,0,2,0,0,0,5]
Nov 29 16:57:07.65: [16366]: --> [7:CONNECT]
Nov 29 16:57:07.65: [16366]: SEND begin page
Nov 29 16:57:07.65: [16366]: <-- data [1025]
Nov 29 16:57:07.65: [16366]: <-- data [1026]
Nov 29 16:57:07.65: [16366]: <-- data [1027]
Nov 29 16:57:07.65: [16366]: <-- data [1031]
Nov 29 16:57:07.65: [16366]: <-- data [1034]
Nov 29 16:57:08.90: [16366]: <-- data [1025]
Nov 29 16:58:28.90: [16366]: MODEM WRITE SHORT: sent 1025, wrote 232
Nov 29 16:58:28.90: [16366]: SENT 44111 bytes of data
Nov 29 16:58:28.90: [16366]: SEND abort data transfer
Nov 29 16:58:28.90: [16366]: <-- data [1]
Nov 29 17:25:34.21: [16366]: SEND end page
Nov 29 17:25:34.21: [16366]: <-- [7:AT+FKS\r]
Nov 29 17:26:04.21: [16366]: MODEM <Timeout>
Nov 29 17:26:04.21: [16366]: <-- [5:ATH0\r]
Nov 29 17:26:09.21: [16366]: MODEM <Timeout>
Nov 29 17:49:02.86: [16366]: SESSION END

-----Ursprüngliche Nachricht-----
Von: Lee Howard [mailto:faxguy@xxxxxxxxxxxxxxxx]
Gesendet: Montag, 29. November 2004 17:44
An: erich.iseli@xxxxxxxxxxxxxxxx
Cc: hylafax-users@xxxxxxxxxxx
Betreff: Re: [hylafax-users] Hylafax very unstable

On 2004.11.29 04:52 erich.iseli@xxxxxxxxxxxxxxxx wrote:

> If at some point I turn off the fax, hell is starting.

What do you mean?  If someone turns off the receiver machine in the
middle of the fax?  Please send a session log.