Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
Re: [hylafax-users] REMOTE HANGUP: No response to EOP repeated 3
> Aug 10 01:37:48.19: [ 2683]: SENT 28148 bytes of data
> Aug 10 01:37:48.19: [ 2683]: <-- data [2]
> Aug 10 01:37:48.37: [ 2683]: SEND end page
> Aug 10 01:37:49.22: [ 2683]: --> [2:OK]
> Aug 10 01:37:49.22: [ 2683]: SEND send EOP (no more pages or documents)
> Aug 10 01:37:49.22: [ 2683]: <-- [9:AT+FET=2\r]
> Aug 10 01:37:59.56: [ 2683]: --> [9:+FHNG: 54]
> Aug 10 01:37:59.56: [ 2683]: REMOTE HANGUP: No response to EOP repeated 3
> times (code 54)
This has been a long standing problem, of course. Unfortunately, it results
in many copies of the fax being sent, since Hylafax thinks that there's been
an error during transmission (which there has been - the receiving end isn't
following the Class 2 protocol, and is hanging up the phone before the
session is over).
I suggest that the code be changed so that if all pages have been successfully
transmitted, that +FHNG be a "success" response to AT+FET=2.
What does everyone think about this as a proposed solution?
____________________ HylaFAX(tm) Users Mailing List _______________________
To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null
*To learn about commercial HylaFAX(tm) support, mail sales@hylafax.org.*