Re: [hylafax-users] Incomplete parts of the fax
MultiTech has released 4.28d firmware for the ISI5634PCI modems. You
could try updating the firmware and using Class 2.1, 2.0, or 2 which
should have ECM capability and would limit the effects of line noise.
You could also try to test to see where the "line noise" is coming
from. If you send a fax from one of the ISI's modems through your
telco to another one of the ISI's modems do those same image anomalies
appear?
Lee.
On 2003.06.27 06:06 Diego Calderon wrote:
> We are using Class 1 and firmware 4.25b
>
> Thanks.
>
> Diego
>
>
> ---------- Original Message -----------
> From: Lee Howard <faxguy@howardsilvan.com>
> To: Diego Calderon <dicalder@mtiamerica.com>
> Cc: hylafax-users@hylafax.org
> Sent: Thu, 26 Jun 2003 17:41:21 -0700
> Subject: Re: [hylafax-users] Incomplete parts of the fax
>
> > On 2003.06.26 16:03 Diego Calderon wrote:
> > > Hi everyone,
> > >
> > > We are starting to use hylaFAX to send faxes (we are receiving
> very
> > > well), but
> > > something happen when we send the fax to a real fax machine. The
> fax
> > > receive
> > > incomplete some lines and in general the fax is no really easy to
> > > read.
> > >
> > > We are using MultiTech ISI5634PCI-8 card, RH 9.0.
> > >
> > > any idea?
> >
> > Are you using Class 1, 2, 2.0, or 2.1 ? And what firmware revision?
> >
> > Thanks.
> >
> > Lee.
> ------- End of Original Message -------
>
____________________ HylaFAX(tm) Users Mailing List _______________________
To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null
*To learn about commercial HylaFAX(tm) support, mail sales@hylafax.org.*