Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
[hylafax-users] problems with Acorp external 56K modem [LONG]
hi!
i have problems with an ACORP 56000 External Data/Fax/Modem.
i'm using the newest hylafax, and it faxes everything to some faxes, but
we've got problems with the other 50% of the faxes.
if you can answer, please cc it to me, because i'm not on the list.
here is the log.
Jun 24 14:18:14.85: [ 6276]: SESSION BEGIN 00000105 361202
Jun 24 14:18:14.85: [ 6276]: HylaFAX (tm) Version 4.1.6
Jun 24 14:18:14.85: [ 6276]: SEND FAX: JOB 6 DEST 202 COMMID 00000105
DEVICE '/dev/ttyS1'
Jun 24 14:18:14.85: [ 6276]: DELAY 75 ms
Jun 24 14:18:14.93: [ 6276]: DELAY 2600 ms
Jun 24 14:18:18.54: [ 6276]: DELAY 10 ms
Jun 24 14:18:18.55: [ 6276]: <-- [4:ATZ\r]
Jun 24 14:18:18.73: [ 6276]: --> [2:OK]
Jun 24 14:18:18.73: [ 6276]: DELAY 3000 ms
Jun 24 14:18:21.73: [ 6276]: <-- [19:AT&F&D2&C1&K3S7=55\r]
Jun 24 14:18:21.84: [ 6276]: --> [18:AT&F&D2&C1&K3S7=55]
Jun 24 14:18:21.84: [ 6276]: --> [2:OK]
Jun 24 14:18:21.84: [ 6276]: <-- [5:ATE0\r]
Jun 24 14:18:21.94: [ 6276]: --> [4:ATE0]
Jun 24 14:18:21.94: [ 6276]: --> [2:OK]
Jun 24 14:18:21.94: [ 6276]: <-- [5:ATV1\r]
Jun 24 14:18:22.04: [ 6276]: --> [2:OK]
Jun 24 14:18:22.04: [ 6276]: <-- [5:ATQ0\r]
Jun 24 14:18:22.14: [ 6276]: --> [2:OK]
Jun 24 14:18:22.14: [ 6276]: <-- [7:ATS0=0\r]
Jun 24 14:18:22.25: [ 6276]: --> [2:OK]
Jun 24 14:18:22.25: [ 6276]: <-- [7:ATS8=2\r]
Jun 24 14:18:22.35: [ 6276]: --> [2:OK]
Jun 24 14:18:22.35: [ 6276]: <-- [8:ATS7=60\r]
Jun 24 14:18:22.45: [ 6276]: --> [2:OK]
Jun 24 14:18:22.46: [ 6276]: <-- [6:AT&K2\r]
Jun 24 14:18:22.56: [ 6276]: --> [2:OK]
Jun 24 14:18:22.56: [ 6276]: <-- [6:AT&D2\r]
Jun 24 14:18:22.65: [ 6276]: --> [2:OK]
Jun 24 14:18:22.66: [ 6276]: <-- [6:AT&C1\r]
Jun 24 14:18:22.75: [ 6276]: --> [2:OK]
Jun 24 14:18:22.76: [ 6276]: <-- [12:AT+FCLASS=1\r]
Jun 24 14:18:22.87: [ 6276]: --> [2:OK]
Jun 24 14:18:22.87: [ 6276]: <-- [7:ATL1M1\r]
Jun 24 14:18:22.96: [ 6276]: --> [2:OK]
Jun 24 14:18:22.97: [ 6276]: <-- [12:AT+FCLASS=1\r]
Jun 24 14:18:23.17: [ 6276]: --> [2:OK]
Jun 24 14:18:23.18: [ 6276]: DIAL 202
Jun 24 14:18:23.18: [ 6276]: <-- [17:AT+FCLASS=1DT202\r]
Jun 24 14:18:37.56: [ 6276]: --> [7:CONNECT]
Jun 24 14:18:39.71: [ 6276]: --> [2:OK]
Jun 24 14:18:39.71: [ 6276]: REMOTE CSI "+36 (1) 319-7122"
Jun 24 14:18:39.71: [ 6276]: <-- [9:AT+FRH=3\r]
Jun 24 14:18:39.73: [ 6276]: --> [7:CONNECT]
Jun 24 14:18:40.44: [ 6276]: --> [2:OK]
Jun 24 14:18:40.44: [ 6276]: REMOTE best rate 14400 bit/s
Jun 24 14:18:40.44: [ 6276]: REMOTE max page width 1728 pixels in 215 mm
Jun 24 14:18:40.44: [ 6276]: REMOTE max unlimited page length
Jun 24 14:18:40.44: [ 6276]: REMOTE best vres 7.7 line/mm
Jun 24 14:18:40.44: [ 6276]: REMOTE best format 1-D MR
Jun 24 14:18:40.44: [ 6276]: REMOTE best 0 ms/scanline
Jun 24 14:18:40.44: [ 6276]: USE 14400 bit/s
Jun 24 14:18:40.44: [ 6276]: USE 0 ms/scanline
Jun 24 14:18:40.44: [ 6276]: SEND file "docq/doc6.cover;00"
Jun 24 14:18:40.44: [ 6276]: USE page width 1728 pixels in 215 mm
Jun 24 14:18:40.44: [ 6276]: USE unlimited page length
Jun 24 14:18:40.44: [ 6276]: USE 3.85 line/mm
Jun 24 14:18:40.44: [ 6276]: USE 1-D MR
Jun 24 14:18:40.44: [ 6276]: SEND training at v.17 14400 bit/s
Jun 24 14:18:40.44: [ 6276]: <-- [9:AT+FTH=3\r]
Jun 24 14:18:40.49: [ 6276]: --> [7:CONNECT]
Jun 24 14:18:40.49: [ 6276]: <-- data [23]
Jun 24 14:18:40.49: [ 6276]: <-- data [2]
Jun 24 14:18:40.52: [ 6276]: --> [7:CONNECT]
Jun 24 14:18:40.52: [ 6276]: <-- data [6]
Jun 24 14:18:40.52: [ 6276]: <-- data [2]
Jun 24 14:18:42.69: [ 6276]: --> [2:OK]
Jun 24 14:18:42.69: [ 6276]: <-- [9:AT+FTS=7\r]
Jun 24 14:18:42.71: [ 6276]: --> [2:OK]
Jun 24 14:18:42.71: [ 6276]: <-- [11:AT+FTM=145\r]
Jun 24 14:18:44.39: [ 6276]: --> [7:CONNECT]
Jun 24 14:18:44.39: [ 6276]: <-- data [1024]
Jun 24 14:18:44.39: [ 6276]: <-- data [1024]
Jun 24 14:18:44.39: [ 6276]: <-- data [652]
Jun 24 14:18:44.39: [ 6276]: <-- data [2]
Jun 24 14:18:45.94: [ 6276]: --> [2:OK]
Jun 24 14:18:45.94: [ 6276]: <-- [9:AT+FRH=3\r]
Jun 24 14:18:46.97: [ 6276]: --> [7:CONNECT]
Jun 24 14:18:49.17: [ 6276]: --> [2:OK]
Jun 24 14:18:49.17: [ 6276]: TRAINING succeeded
Jun 24 14:18:49.17: [ 6276]: DELAY 75 ms
Jun 24 14:18:49.25: [ 6276]: <-- [11:AT+FTM=146\r]
Jun 24 14:18:49.75: [ 6276]: --> [7:CONNECT]
Jun 24 14:18:49.75: [ 6276]: SEND begin page
Jun 24 14:18:49.75: [ 6276]: <-- data [1028]
Jun 24 14:18:49.75: [ 6276]: <-- data [1032]
Jun 24 14:18:49.75: [ 6276]: <-- data [1041]
Jun 24 14:18:49.75: [ 6276]: <-- data [1043]
Jun 24 14:18:51.75: [ 6276]: <-- data [1039]
Jun 24 14:18:51.75: [ 6276]: <-- data [1063]
Jun 24 14:18:51.75: [ 6276]: <-- data [1043]
Jun 24 14:18:51.75: [ 6276]: <-- data [1046]
Jun 24 14:18:53.75: [ 6276]: <-- data [1036]
Jun 24 14:18:53.75: [ 6276]: <-- data [1037]
Jun 24 14:18:53.75: [ 6276]: <-- data [1024]
Jun 24 14:18:53.75: [ 6276]: <-- data [196]
Jun 24 14:18:53.75: [ 6276]: SENT 11460 bytes of data
Jun 24 14:18:53.75: [ 6276]: SEND 1D RTC
Jun 24 14:18:53.75: [ 6276]: <-- data [29]
Jun 24 14:18:53.75: [ 6276]: <-- data [2]
Jun 24 14:18:53.75: [ 6276]: SEND end page
Jun 24 14:18:56.42: [ 6276]: --> [2:OK]
Jun 24 14:18:56.42: [ 6276]: <-- [9:AT+FTS=7\r]
Jun 24 14:18:56.44: [ 6276]: --> [2:OK]
Jun 24 14:18:56.44: [ 6276]: SEND send MPS (more pages, same document)
Jun 24 14:18:56.44: [ 6276]: <-- [9:AT+FTH=3\r]
Jun 24 14:18:56.49: [ 6276]: --> [7:CONNECT]
Jun 24 14:18:56.49: [ 6276]: <-- data [3]
Jun 24 14:18:56.49: [ 6276]: <-- data [2]
Jun 24 14:18:57.81: [ 6276]: --> [2:OK]
Jun 24 14:18:57.81: [ 6276]: <-- [9:AT+FRH=3\r]
Jun 24 14:19:00.91: [ 6276]: --> [0:]
Jun 24 14:19:00.91: [ 6276]: MODEM <Empty line>
Jun 24 14:19:00.91: [ 6276]: <-- data [1]
Jun 24 14:19:01.11: [ 6276]: MODEM <Timeout>
Jun 24 14:19:01.11: [ 6276]: SEND send MPS (more pages, same document)
Jun 24 14:19:01.11: [ 6276]: <-- [9:AT+FTH=3\r]
Jun 24 14:19:01.16: [ 6276]: --> [7:CONNECT]
Jun 24 14:19:01.16: [ 6276]: <-- data [3]
Jun 24 14:19:01.16: [ 6276]: <-- data [2]
Jun 24 14:19:02.48: [ 6276]: --> [2:OK]
Jun 24 14:19:02.48: [ 6276]: <-- [9:AT+FRH=3\r]
Jun 24 14:19:05.58: [ 6276]: --> [0:]
Jun 24 14:19:05.58: [ 6276]: MODEM <Empty line>
Jun 24 14:19:05.58: [ 6276]: <-- data [1]
Jun 24 14:19:05.78: [ 6276]: MODEM <Timeout>
Jun 24 14:19:05.78: [ 6276]: SEND send MPS (more pages, same document)
Jun 24 14:19:05.78: [ 6276]: <-- [9:AT+FTH=3\r]
Jun 24 14:19:05.83: [ 6276]: --> [7:CONNECT]
Jun 24 14:19:05.83: [ 6276]: <-- data [3]
Jun 24 14:19:05.83: [ 6276]: <-- data [2]
Jun 24 14:19:07.15: [ 6276]: --> [2:OK]
Jun 24 14:19:07.15: [ 6276]: <-- [9:AT+FRH=3\r]
Jun 24 14:19:10.25: [ 6276]: --> [0:]
Jun 24 14:19:10.25: [ 6276]: MODEM <Empty line>
Jun 24 14:19:10.25: [ 6276]: <-- data [1]
Jun 24 14:19:10.45: [ 6276]: MODEM <Timeout>
Jun 24 14:19:10.45: [ 6276]: No response to MPS or EOP repeated 3 tries
Jun 24 14:19:10.45: [ 6276]: SEND: No response to MPS or EOP repeated 3
tries; Giving up after 3 attempts to send same page "docq/doc6.cover;00",
dirnum 0
Jun 24 14:19:10.45: [ 6276]: <-- [9:AT+FTH=3\r]
Jun 24 14:19:10.50: [ 6276]: --> [7:CONNECT]
Jun 24 14:19:10.50: [ 6276]: <-- data [3]
Jun 24 14:19:10.50: [ 6276]: <-- data [2]
Jun 24 14:19:11.82: [ 6276]: --> [2:OK]
Jun 24 14:19:11.82: [ 6276]: <-- [5:ATH0\r]
Jun 24 14:19:12.25: [ 6276]: --> [10:NO CARRIER]
Jun 24 14:19:12.25: [ 6276]: MODEM No carrier
Jun 24 14:19:12.25: [ 6276]: SESSION END
When it starts, it seems like working, but later it drops the carrier. and
i don't know why. we tried the modem in a fax machine with windows, and
there it worked. we tried those init strings, but the problem remained the
same.
Here is the config:
CountryCode: 36
AreaCode: 1
FAXNumber: +36.1.319.xxxx
LongDistancePrefix: 06
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing: 1
SessionTracing: 11
RecvFileMode: 0600
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 1
SpeakerVolume: low
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "R-mediaLine"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "From %%l|%c|Page %%P of %%T"
MaxRecvPages: 25
Use2D: yes
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class1 # use this to supply a hint
ModemRate: 19200 # rate for DCE-DTE communication
ModemFlowControl: rtscts # RTS/CTS flow control assumed
ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
#
# We can append the "@" symbol to the dial string so that
# the modem will wait 5 seconds before attempting to connect
# and return result codes that distinguish between no carrier
# and no answer. This makes it possible to avoid problems with
# repeatedly dialing a number that doesn't have a fax machine
# (kudos to Stuart Lynne for this trick.)
#
# NB: If you need to prefix phone numbers to get through a PBX,
# put it in the ModemDialCmd; e.g. "DT9%s@".
#
ModemDialCmd: AT+FCLASS=1DT%s # T for tone dialing
#
# Other possible configuration stuff. The default strings are
# shown below. Only those that are different from the defaults
# need to be included in the configuration file.
#
#ModemResetCmds: AT+FCLASS=1
ModemResetCmds: AT&F&D2&C1&K3S7=55
ModemAnswerCmd: ATA # use this to answer phone
#ModemNoFlowCmd: AT&K # disable flow control cmd
#ModemHardFlowCmd: AT&K3 # hardware flow control cmd
ModemSoftFlowCmd: AT&K2 # software flow control cmd
ModemNoAutoAnswerCmd: ATS0=0 # disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
ModemEchoOffCmd: ATE0 # disable command echo
ModemVerboseResultsCmd: ATV1 # enable verbose command results
ModemResultCodesCmd: ATQ0 # enable result codes
ModemOnHookCmd: ATH0 # place phone on hook (hangup)
ModemSoftResetCmd: ATZ # do soft reset of modem
ModemWaitTimeCmd: ATS7=60 # wait 60 seconds for carrier
ModemCommaPauseTimeCmd: ATS8=2 # comma pause time is 2 seconds
ModemRecvFillOrder: LSB2MSB # bit order of received facsimile
ModemSendFillOrder: LSB2MSB # bit order modem expects for transmit
#Class1Cmd: AT&F&D2&C1&K&S7=55+FCLASS=1 # command to enter class 1
#Class1PPMWaitCmd: AT+FTS=7 # command to stop and wait before PPM
#Class1TCFWaitCmd: AT+FTS=7 # command to stop and wait before TCF
#Class1EOPWaitCmd: AT+FTS=9 # command to stop and wait before EOP
Class1MsgRecvHackCmd: "" # command to avoid +FCERROR before image
Class1TCFResponseDelay: 75 # 75ms delay between recv TCF & response
Class1SendMsgDelay: 75 # 75ms delay after training
Class1SwitchingCmd: AT+FRS=7 # silence between HDLC recv and trans
Class1TrainingRecovery: 1500 # 1.5sec delay after training failure
Class1RecvAbortOK: 200 # wait 200ms for abort response
Class1FrameOverhead: 4 # 4 byte overhead in recvd HDLC frames
Class1RecvIdentTimer: 40000 # 35+5secs waiting for ident frames
Class1TCFMaxNonZero: 10 # max 10% of data may be non-zero
Class1TCFMinRun: 1000 # min run is 2/3rds of TCF duration
Class1NFLOCmd:AT&H0&I0&R1 # setup modem for no flow control
#Class1HFLOCmd:AT&H1&I0&R2 # setup modem for hardware flow control
#Class1SFLOCmd:"" # modem does this automatically
#ModemWaitForConnect: yes
I tried several types of flow control, maybe i made some mistake.
and finally, probemodem's output:
Probing for best speed to talk to modem: 38400 OK.
This looks like a Class 1 modem.
ATI0 RESULT = "OK" RESPONSE = "TP560 Data/Fax/Voice 56K Modem"
ATI1 RESULT = "OK" RESPONSE = "External Controller Ver3.00,
CheckSum=B394"
ATI2 RESULT = "OK" RESPONSE = "TEST OK!"
ATI3 RESULT = "OK" RESPONSE = "TP560 Data/Fax/Voice 56K Modem"
ATI4 RESULT = "OK" RESPONSE = "DSP Ver3.00 CheckSum=7643"
ATI5 RESULT = "OK" RESPONSE = "CTR21 Complex Impedence"
ATI6 RESULT = "OK" RESPONSE = "1"
ATI7 RESULT = "OK" RESPONSE = "Controller Ver3.00 Date:Dec 05 18:02
2001"
ATI8 RESULT = "OK" RESPONSE = "DSP Ver3.00 Date:Nov 02 14:11 2001"
ATI9 RESULT = "OK" RESPONSE = "Software Speakerphone"
Class 1 stuff...
AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,8"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=1 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FJUNK=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FJUNK? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAA=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAA? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAE=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAE? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FTH=? RESULT = "OK" RESPONSE = "3"
AT+FRH=? RESULT = "OK" RESPONSE = "3"
AT+FTM=? RESULT = "OK" RESPONSE =
"24,48,72,73,74,96,97,98,121,122,145,146"
AT+FRM=? RESULT = "OK" RESPONSE =
"24,48,72,73,74,96,97,98,121,122,145,146"
AT+FTS=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FRS=? RESULT = "ERROR" RESPONSE = "ERROR"
it would be great if you can help me. i'm getting mad. :~~>
--
dp
____________________ HylaFAX(tm) Users Mailing List _______________________
To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null
*To learn about commercial HylaFAX(tm) support, mail sales@hylafax.org.*