Re: [hylafax-users] Problems with CVS



On 2003.03.17 16:55 Frank Peters wrote:
> I downloaded the latest CVS.  In order to get it to compile,
> using gcc-3.2.2, I had to make two corrections:
> 
> 1). The configure script does not recognize the latest
> release of libtiff-3.6.0-beta.  I had to alter line 2317
> to include "3.6" instead of "3.5".

Thanks for pointing this out.  This will be addressed in the next 
release.

> 2). Hfaxd would not compile due to errors produced with
> OldProtocol.c++.  Since I do not use the old protocol, I
> altered the Makefile in the /src/hfaxd directory by eliminating
> the -DOLDPROTO_SUPPORT=1.

Could you post the exact errors, please?

> After these two corrections, the CVS source successfully compiled.
> 
> Then I tried to receive a fax in 2D-MMR and the logs showed
> a successful receipt.  However, I could not view the file.
> 
> Using tiffinfo, the following error was produced on the received
> tiff file:
> 
> [recvq]# tiffinfo fax00001.tif
> 
> fax00001.tif: Warning, incorrect count for field "StripOffsets" (1,
> expecting 0); tag ignored.
> fax00001.tif: Warning, incorrect count for field "StripByteCounts" (1,
> expecting 0); tag ignored.
> 
> TIFF Directory at offset 0xb4e6
>   Subfile Type: multi-page document (2 = 0x2)
>   Image Width: 1728 Image Length: 0
>   Resolution: 204, 98 pixels/inch
>   Bits/Sample: 1
>   Compression Scheme: CCITT Group 4
>   Photometric Interpretation: min-is-white
>   FillOrder: lsb-to-msb
>   Date & Time: "2003:03:16 15:01:21"
>   Host Computer: "localhost.localdomain"
>   Image Description: ""
>   Make: "MULTI-TECH SYSTEMS"
>   Model: "MT5634ZPX-PCI-V92"
>   Orientation: row 0 top, col 0 lhs
>   Samples/Pixel: 1
>   Rows/Strip: (infinite)
>   Planar Configuration: single image plane
>   Software: HylaFAX (tm) Version 4.1.5
>   Group 4 Options: (0 = 0x0)
>   Fax Data: clean (0 = 0x0)
>   Fax Receive Parameters: 0021e028
>   Fax Receive Time: 32 secs

Most of the MT5634 modems corrupt MMR data with firmware revisions less 
than 1.28.  If you're using version 1.25, then you'll likely need to 
disable MMR with ModemAnswerCmd and Class2DCCQueryCmd... get new 
firmware, or use Class 1 (which doesn't support MMR).

Lee.

____________________ HylaFAX(tm) Users Mailing List _______________________
  To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
 On UNIX: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null
  *To learn about commercial HylaFAX(tm) support, mail sales@hylafax.org.*



Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services