Hi!
On Thu, 8 Nov 2001, Miles K. Forrest wrote:
> I ran across your message on the HylaFAX mailing list. Is your
> installation of HylaFAX working well? I have a new Zyxel Omni 56K
> running at a client of mine, and they're experiencing a large percentage
> of failed receives.
>
> Did you/do you have many problems with your setup?
>
> Thanks for your time,
>
> Miles K. Forrest
> soon-to-be-loosing-my-hair-over-this :-)
The only problem is that sometimes modem goes wedged. The solution is
simple restart faxgetty. Now my cron do it. AFAIU it is a problem of
faxgetty but I have no time to debug now.
First of all I put the latest firmware (1.09) to modem. Here is my config:
....
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2.0 # use class 2.0 interface
ModemRate: 38400 # 38.4 works fine
ModemFlowControl: rtscts # default
#
ModemNoFlowCmd: AT&H0 # disable flow control
ModemHardFlowCmd: AT&H3 # hardware flow control
ModemSoftFlowCmd: AT&H4 # software flow control
ModemSetupDTRCmd: AT&D2 # DTR off causes modem to hang up
ModemSetupDCDCmd: AT&C1 # DCD tracks carrier
#
AdaptiveAnswer: off
#ModemSetupAACmd: AT+FAA=1 # enable in current class
#
# Additional reset commands:
#
# &B1 DTE-DCE rate is fixed at DTE setting
# &N0 Auto-negotiate highest possible DCE-DCE link rate
# &S0 DSR always on
# *F0 Deny remote configuration
# (actually *F0 doesn't work in the firmware -- sigh)
# S18=4 Receive at 38400
# S38.3=1 DCD on/off sequence follows UNIX standard; also
# fix receiving baud rate at S18 value
#
#ModemResetCmds: AT&B1&N0&S0S18=4S38.3=1*p4s8=6
ModemResetCmds: AT&B1s8=6*p3
#
#
# We don't want unlimited page length
# original Omni was: (0,1),(0-5),(0-2),(0-2),(0,1),(0),(0),(0-7)
#
# A4 length:
Class2DCCQueryCmd: !(0,1),(0-5),(0-2),(0),(0,1),(0),(0),(0-7)
#
# A4 length, limit speed <= 9600:
#Class2DCCQueryCmd: !(0,1),(0-3),(0-2),(0),(0,1),(0),(0),(0-7)
#
# A4,B4 length:
#
#Class2DCCQueryCmd: !(0,1),(0-5),(0-2),(0,1),(0,1),(0),(0),(0-7)
#
NoCarrierRetrys: 3 # retry 3 times on no carrier
#
ModemSetVolumeCmd: "ATM0 ATM1L1 ATM1L3 ATM1L5 ATM1L7"
--------------------------------------