Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
[hylafax-users] Re: multitech
Adam Bisbe wrote:
>
> Hi all:
>
> Can someone suggest a config file for:
>
> MULTITECH MT2834
>
> thank you.
>
> ____________________ HylaFAX(tm) Users Mailing List _______________________
> To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null
these work fine for us
the config.mt1432 is for the MT models
the config.zdx is for the ZDX Models
HIH
/matthias
--
HAGOS eG phone: +49 711 7880592
Matthias Reich fax: +49 711 7880599
Industriestr. 62 web: http://www.hagos.de
D-70565 Stuttgart mail: rei@hagos.de
Germany
----------------------------------------------------------------------------
Be careful your mail is read by the NSA too !!
# $Id: mt-1432,v 1.23 1996/06/24 02:58:36 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
#
# Configuration for a Multi-Tech MT1432, MT224BA, and MT1932ZDX modems.
#
# MT1432 firmware rev 0307 I or newer
# MT132BG rev 0109A
# MT1932ZDX rev 0109H
#
# Note that MT1432 modems come in several varieties:
#
# MT1432BA uses Rockwell data pump
# MT1432BA/A uses AT&T data pump
# MT1432BG MT1432BA tweaked for German FCC
# MT1432MK (for UK?)
#
# The modem has been tried with both XON/XOFF and RTS/CTS flow
# control; this configuration is for hardware flow control.
#
#
CountryCode: 49
AreaCode: 0711
FAXNumber: +49.711.7880549
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: "etc/dialrules"
ServerTracing: 0
SessionTracing: 0
RecvFileMode: 0600
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 3
SpeakerVolume: off
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "HAGOS eG Stuttgart"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: " Von %%n %%l|%c|Seite %%p von %%t"
PercentGoodLines: 90
MaxConsecutiveBadLines: 10
MaxRecvPages: 25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use class 2 interface
ModemRate: 38400 # lock rate for DCE-DTE communication
ModemFlowControl: rtscts # default
ModemResetCmds: AT&FX3
#
ModemHardFlowCmd: AT&E4 # hardware flow control
ModemSoftFlowCmd: AT&E5 # software flow control
ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in class 2
#
# NB: some models get confused by the @
#
ModemDialCmd: ATDT0,%s
#
Class2RecvDataTrigger: "\022" # character sent to modem to start recv
# $Id: class2,v 1.23 1996/06/24 02:58:32 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
#
# Generic Class 2 modem configuration.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode: 49
AreaCode: 711
FAXNumber: +49.711.7880549
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing: 0x00040
SessionTracing: 0
RecvFileMode: 0600
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 0
SpeakerVolume: off
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "HAGOS eG Stuttgart"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: " Von %%l|%c|Seite %%p von %%t"
QualifyTSI: etc/tsi
PercentGoodLines: 90
MaxConsecutiveBadLines: 10
MaxRecvPages: 25
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use class 2 interface
ModemRate: 38400 # lock rate for DCE-DTE communication
ModemFlowControl: rtscts # default
#
ModemResetCmds: AT&FX3
ModemHardFlowCmd: AT&E4 # hardware flow control
ModemSoftFlowCmd: AT&E5 # software flow control
ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in class 2
#
# NB: some models get confused by the @
#
ModemDialCmd: ATDT0,%s
#
Class2RecvDataTrigger: "\022" # character sent to modem to start recv
#