Hylafax Mailing List Archives

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Class 2 config file for MT5600ZDX



Hi All,

I had been struggling with the config file for a RECENT (last 3 months)
Multitech MT5600ZDX (one that really seems to have Class 2 added back in).
Anyways, I managed to finally come up with a config that supported faxing
(in and out) and data (in and out).  Thought I would share it with the
group in case someone might be looking for it and/or could improve on it.

FWIW,

Mark

==========================================================================

# $Id: class2,v 1.2 1999/01/10 09:09:37 robert Exp $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
# 
# Permission to use, copy, modify, distribute, and sell this software and 
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
# 
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
# 
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
# OF THIS SOFTWARE.
#

#
# Generic Class 2 modem configuration.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode:		1
AreaCode:		999
FAXNumber:		+1.999.888.7777
LongDistancePrefix:	1
InternationalPrefix:	011
DialStringRules:	etc/dialrules
#
# ServerTracing:	11
ServerTracing:		1
#
# SessionTracing:	11
SessionTracing:		1
#
LogFileMode:		0644
RecvFileMode:		0644
DeviceMode:		0666
#
RingsBeforeAnswer:	2
#
#SpeakerVolume:		off
SpeakerVolume:		high
#
GettyArgs:		"-h -t 120 %l DT%s vt100"
#
UUCPLockDir:		"/var/lock/"
#
LocalIdentifier:	+YourIDHere
#
LogFacility:		local5
#
TagLineFont:		etc/lutRS18.pcf
TagLineFormat:		"From %%l|%c|Page %%p of %%t"
#
MaxRecvPages:		100
Use2D:			No
#
IXOMaxUnknown:		10
IXOIDProbe:		6
IXOLoginTimeout:	30

#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:		Class2		# use this to supply a hint
#
#ModemRate:		19200		# max rate for DCE-DTE communication
ModemRate:		38400		# max rate for DCE-DTE communication
#
#ModemFlowControl:	xonxoff		# XON/XOFF flow control assumed
ModemFlowControl:	rtscts		# XON/XOFF flow control assumed
#
#ModemSetupDTRCmd:	AT&D2		# setup so DTR drop resets modem
#ModemSetupDCDCmd:	AT&C1		# setup so DCD reflects carrier (or not)
#
# We normally append the "@" symbol to the dial string so that
# the modem will wait 5 seconds before attempting to connect
# and return result codes that distinguish between no carrier
# and no answer.  This makes it possible to avoid problems with
# repeatedly dialing a number that doesn't have a fax machine
# (kudos to Stuart Lynne for this trick.)
#
# NB: If you need to prefix phone numbers to get through a PBX,
#     put it in the ModemDialCmd; e.g. "DT9%s@".
#
#ModemDialCmd:		ATDT%s@		# T for tone dialing, @ for silence
ModemDialCmd:		ATDT%s		# T for tone dialing, @ for silence
#
# Other possible configuration stuff.  The default strings are
# shown below.  Only those that are different from the defaults
# need to be included in the configuration file.
#
#ModemResetCmds:	""		# stuff to do when modem is reset
#ModemAnswerCmd:	ATA		# use this to answer phone
#ModemNoFlowCmd:	AT&K		# disable flow control cmd
#ModemHardFlowCmd:	AT&K3		# hardware flow control cmd
#ModemSoftFlowCmd:	AT&K4		# software flow control cmd
#ModemNoAutoAnswerCmd:	ATS0=0		# disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
#ModemSetVolumeCmd:	"ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
#ModemEchoOffCmd:	ATE0		# disable command echo
#ModemVerboseResultsCmd:	ATV1		# enable verbose command results
#ModemResultCodesCmd:	ATQ0		# enable result codes
#ModemOnHookCmd:		ATH0		# place phone on hook (hangup)
#ModemSoftResetCmd:	ATZ		# do soft reset of modem
#ModemWaitTimeCmd:	ATS7=60		# wait 60 seconds for carrier
#ModemCommaPauseTimeCmd:	ATS8=2		# comma pause time is 2 seconds
ModemRecvFillOrder:	MSB2LSB		# bit order of received facsimile
ModemSendFillOrder:	LSB2MSB		# bit order modem expects for transmit
#
ModemSetupAACmd:	AT+FAA=1+FCLASS=0	# enable adaptive-answer in class 2
#
CLocalAsRoot:		yes
#
ModemWaitForConnect:	yes
#
# Configuration parameters for Class 2 modems.
#
Class2Cmd:		AT+FCLASS=2	# command to enter class 2
Class2BORCmd:		AT+FBOR=0	# bit order for phase B/C/D (direct)
Class2RELCmd:		AT+FREL=1	# byte-align EOL codes on recv
Class2CQCmd:		""		# commands to enable copy quality proc.
Class2AbortCmd:		AT+FK		# abort session command
Class2CQQueryCmd:	AT+FCQ=?	# query for copy quality capabilities
Class2DCCQueryCmd:	AT+FDCC=?	# query for modem capabilities
Class2TBCCmd:		AT+FTBC=0	# setup stream mode
Class2CRCmd:		AT+FCR=1	# enable capability to receive
Class2PHCTOCmd:		AT+FPHCTO=30	# set phase C timeout parameter
Class2BUGCmd:		AT+FBUG=1	# enable HDLC frame tracing
Class2LIDCmd:		AT+FLID		# set local identifier command
Class2DCCCmd:		AT+FDCC		# set modem capabilities command
Class2DISCmd:		AT+FDIS		# set session parameters command
Class2DDISCmd:		""		# disable pre-dial DIS command hack
Class2CIGCmd:		AT+FCIG		# set polling identifier command
Class2PTSCmd:		AT+FPTS		# set post-page status command
Class2SPLCmd:		AT+FSPL		# set polling indicator command
#
# If Class2RecvDataTrigger is not set, then it is set to DC1
#
Class2RecvDataTrigger:	"\022"
Class2XmitWaitForXON:	yes		# if true, wait for XON before send



Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services