Hylafax Mailing List Archives

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: --> [8:+FHNG:22] REMOTE HANGUP: COMREC error in transmit Phase



> Aug 09 13:50:10.13: [32321]: <-- [31:AT+FLID="Allscripts Inc. - Al"\r]

Probably not the problem, but I would try using a legal value for the
station ID (basically international phone number characters only).

> Aug 09 13:50:25.32: [32321]: --> [5:+FCON]
> Aug 09 13:50:27.14: [32321]: --> [74:+FHR:FF 03 C1 20 20 20 20 20 20 20 20
> 20 20 20 20 20 20 20 20 33 34 39 35 ]

Looks like an unrecognized inbound message ending in "                3495".

> Aug 09 13:50:28.14: [32321]: --> [14:+FHT:FF 13 FA ]

At a guess, your modem decided to abandon hope and aborted the connection.

> Aug 09 13:50:28.60: [32321]: --> [8:+FHNG:22]

It dropped the line.

You might have luck with a different modem, or in Class 1, if possible,
as they may be more forgiving.



Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services