Re: FW: facsimile not received ????




On 01-Feb-99 Hong Kong Observatory wrote:
> Hi,
> 
>    I think you have to submit information on your modem model, operating
> system, modem config files.....
> 
> 

Modem Lasat unique 1280mi
at+fclass=?
z0,1,2,1.0,80 

Linux on Intel Kernel 2.0.36

calvin$ cat config
LogFacility:            local5
CountryCode:            49
AreaCode:               721
LongDistancePrefix:     0
InternationalPrefix:    00
DialStringRules:        etc/dialrules.europe
ServerTracing:          1
ModemClass:             2                


cat config.ttyS0
# $Id: class2,v 1.23 1996/06/24 02:58:32 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#

#
# Generic Class 2 modem configuration.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode:            49
AreaCode:               721
FAXNumber:              +49 721 9891004
LongDistancePrefix:     0
InternationalPrefix:    00
DialStringRules:        etc/dialrules.europe
ServerTracing:          1
SessionTracing:         11
RecvFileMode:           0600
LogFileMode:            0600    
DeviceMode:             0600
RingsBeforeAnswer:      1
SpeakerVolume:          off
GettyArgs:              "-h %l dx_%s"
LocalIdentifier:        "Ruediger Gubler"
TagLineFont:            etc/lutRS18.pcf
TagLineFormat:          "From %%l|%c|Page %%p of %%t"
MaxRecvPages:           9999
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:              Class2          # use this to supply a hint
ModemRate:              38400
ModemFlowControl:       rtscts
ModemSetupDTRCmd:       AT&D2           # setup so DTR drop resets modem
ModemSetupDCDCmd:       AT&C1           # setup so DCD reflects carrier (or not)
#
# We normally append the "@" symbol to the dial string so that
# the modem will wait 5 seconds before attempting to connect
# and return result codes that distinguish between no carrier
# and no answer.  This makes it possible to avoid problems with
# repeatedly dialing a number that doesn't have a fax machine
# (kudos to Stuart Lynne for this trick.)
#
# NB: If you need to prefix phone numbers to get through a PBX,
#     put it in the ModemDialCmd; e.g. "DT9%s@".
#
ModemDialCmd:           ATDT%s@         # T for tone dialing, @ for silence
#
# Other possible configuration stuff.  The default strings are
# shown below.  Only those that are different from the defaults
# need to be included in the configuration file.
#
ModemResetCmds:         ""              # stuff to do when modem is reset
ModemAnswerCmd:         ATA             # use this to answer phone
ModemNoFlowCmd:         AT&K            # disable flow control cmd
ModemHardFlowCmd:       AT&K3           # hardware flow control cmd
ModemSoftFlowCmd:       AT&K4           # software flow control cmd
ModemNoAutoAnswerCmd:   ATS0=0          # disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
ModemSetVolumeCmd:      "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
ModemEchoOffCmd:        ATE0            # disable command echo
ModemVerboseResultsCmd: ATV1            # enable verbose command results
ModemResultCodesCmd:    ATQ0            # enable result codes
ModemOnHookCmd:         ATH0            # place phone on hook (hangup)
ModemSoftResetCmd:      ATZ&Z*=9891004%M1               # do soft reset of modem
ModemWaitTimeCmd:       ATS7=60         # wait 60 seconds for carrier
ModemCommaPauseTimeCmd: ATS8=2          # comma pause time is 2 seconds
ModemRecvFillOrder:     LSB2MSB         # bit order of received facsimile
ModemSendFillOrder:     LSB2MSB         # bit order modem expects for transmit 
#
# Configuration parameters for Class 2 modems.
#
Class2Cmd:              AT+FCLASS=2     # command to enter class 2
Class2BORCmd:           AT+FBOR=0       # bit order for phase B/C/D (direct)
Class2RELCmd:           AT+FREL=1       # byte-align EOL codes on recv
Class2CQCmd:            ""              # commands to enable copy quality proc.
Class2AbortCmd:         AT+FK           # abort session command
Class2CQQueryCmd:       AT+FCQ=?        # query for copy quality capabilities
Class2DCCQueryCmd:      AT+FDCC=?       # query for modem capabilities
Class2TBCCmd:           AT+FTBC=0       # setup stream mode
Class2CRCmd:            AT+FCR=1        # enable capability to receive
Class2PHCTOCmd:         AT+FPHCTO=30    # set phase C timeout parameter
Class2BUGCmd:           AT+FBUG=1       # enable HDLC frame tracing
Class2LIDCmd:           AT+FLID         # set local identifier command
Class2DCCCmd:           AT+FDCC         # set modem capabilities command
Class2DISCmd:           AT+FDIS         # set session parameters command
Class2DDISCmd:          ""              # disable pre-dial DIS command hack
Class2CIGCmd:           AT+FCIG         # set polling identifier command
Class2PTSCmd:           AT+FPTS         # set post-page status command
Class2SPLCmd:           AT+FSPL         # set polling indicator command
#
# If Class2RecvDataTrigger is not set, then it is set to DC1
#
Class2RecvDataTrigger:  ""              # character sent to modem to start recv
Class2XmitWaitForXON:   yes             # if true, wait for XON before send  


> On Fri, 29 Jan 1999, Ruediger Gubler wrote:
> 
>> 
>> Why???
>> 
>> Jan 29 10:25:30.56: [ 6470]: --> [22:+FDCS: 0,5,0,2,0,0,0,0]
>> Jan 29 10:25:30.56: [ 6470]: REMOTE wants 14400 bit/s
>> Jan 29 10:25:30.56: [ 6470]: REMOTE wants page width 1728 pixels in 215 mm
>> Jan 29 10:25:30.56: [ 6470]: REMOTE wants unlimited page length 
>> Jan 29 10:25:30.56: [ 6470]: REMOTE wants 3.85 line/mm
>> Jan 29 10:25:30.56: [ 6470]: REMOTE wants 1-D MR
>> Jan 29 10:25:30.56: [ 6470]: --> [2:OK]
>> Jan 29 10:25:30.56: [ 6470]: <-- [7:AT+FDR\r]
>> Jan 29 10:25:33.84: [ 6470]: --> [5:+FCFR]
>> Jan 29 10:25:37.39: [ 6470]: --> [22:+FDCS: 0,5,0,2,0,0,0,0]
>> Jan 29 10:25:37.39: [ 6470]: REMOTE wants 14400 bit/s
>> Jan 29 10:25:37.39: [ 6470]: REMOTE wants page width 1728 pixels in 215 mm
>> Jan 29 10:25:37.39: [ 6470]: REMOTE wants unlimited page length 
>> Jan 29 10:25:37.39: [ 6470]: REMOTE wants 3.85 line/mm
>> Jan 29 10:25:37.39: [ 6470]: REMOTE wants 1-D MR
>> Jan 29 10:25:37.39: [ 6470]: --> [7:CONNECT]
>> Jan 29 10:25:37.39: [ 6470]: RECV: begin page
>> Jan 29 10:25:37.39: [ 6470]: RECV: send trigger 021
>> Jan 29 10:25:45.91: [ 6470]: RECV: 608 total lines, 606 bad lines, 567
>> consecutive bad lines
>> Jan 29 10:25:45.91: [ 6470]: --> [17:+FPTS: 1,2219,0,0]
>> Jan 29 10:25:48.07: [ 6470]: --> [7:+FET: 2]
>> Jan 29 10:25:48.07: [ 6470]: RECV recv EOP (no more pages or documents)
>> Jan 29 10:25:48.07: [ 6470]: --> [2:OK]
>> Jan 29 10:25:48.07: [ 6470]: RECV: REJECT page quality, 0% good lines (95%
>> required)
>> Jan 29 10:25:48.07: [ 6470]: RECV send RTN (retrain negative)
>> Jan 29 10:25:48.07: [ 6470]: <-- [10:AT+FPTS=2\r]
>> Jan 29 10:25:48.24: [ 6470]: --> [2:OK]
>> Jan 29 10:25:48.24: [ 6470]: <-- [7:AT+FDR\r]
>> Jan 29 10:25:52.35: [ 6470]: --> [8:+FHNG: 0]
>> Jan 29 10:25:52.35: [ 6470]: REMOTE HANGUP: Normal and proper end of
>> connection
>> (code 0)
>> Jan 29 10:25:52.35: [ 6470]: RECV FAX (00000008): recvq/fax00003.tif from
>> +49
>> 7243 541750, route to <unspecified>, 0 pages in 0
>> :24
>> Jan 29 10:25:52.35: [ 6470]: RECV FAX: Normal and proper end of connection
>> Jan 29 10:25:52.35: [ 6470]: RECV FAX (00000008): session with +49 7243
>> 541750
>> terminated abnormally: Normal and proper end of 
>> connection
>> Jan 29 10:25:52.35: [ 6470]: RECV FAX: bin/faxrcvd "recvq/fax00003.tif"
>> "ttyS0"
>> "00000008" "Normal and proper end of connection
>> "
>> 
>> --------------End of forwarded message-------------------------
>> 
>> ---
>> 
>> E-Mail: Ruediger Gubler <ruediger.gubler@plannet.de>
>> Date: 29-Jan-99
>> Time: 10:30:32
>> 
>> Old musicians never die, they just decompose.
>> 
>> 
> 
> K.S.Wat SSA(D)12
> Computer Division,
> Hong Kong Observatory.

---

E-Mail: Ruediger Gubler <ruediger.gubler@plannet.de>
Date: 01-Feb-99
Time: 12:21:39

My cup hath runneth'd over with love.