Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
Re: RTN Problem
Ulrich Mueller wrote:
>
> Robert Colquhoun writes:
>
> > Hi Ulrich,
>
> [ Now there are two people who asked almost the same question at the
> same time, and by coincidence we have the same first name, too.
> Don't be confused. ;-) ]
>
> > This is my list for handling negative-retrains from selected
> > receiving locations(ie you are getting them from some locations,
> > *not* everywhere you send):
>
> That is exactly the behaviour I observe.
> > 4) Try class 1, just in case there is something funny in the modems
> > firmware
>
> Class 1 works! It really seems to point to a modem problem.
>
> > 5) Try another modem, apart from a Zyxel 1496/6.19 ;-)
>
> Ulrich, could you confirm that you have the same modem? You did not
> mention it in your original question.
>
> --
> Ulrich Mueller, Inst. fuer Kernphysik, Univ. Mainz, D-55099 Mainz
> ulm@kph.uni-mainz.de, Phone +49 6131 39-5812, Fax -2964
Hi,
i have here a ZYXEL U1496E/V 6.15 P, so there may be differences.
I will have a look at the error stats this evening and will see,
if we get fewer errors (we have in fact some very bad lines to
some of our customers). So i hope that these patches will help
here.
Brgs
Uli
--
Ulrich Eckhardt Tr@nscom GbR
http://people.frankfurt.netsurf.de/uli http://www.transcom.de
Lagerstraße 11-15 A8
64807 Dieburg Germany