Re: RTN Problem
Hi Ulrich,
At 16:54 2/12/98 +0100, Ulrich Mueller wrote:
>Is this related to the comment on the Hylafax modem WWW page
>concerning Zyxel
>(http://www.hylafax.org/Modems/zyxel-1496.html#Class2.0):
>
>| When transmitting, it is not necessary to send RTC, the modem will
>| append RTC to the page data upon receiving the post-page message
>| from the host.
>
>Or is it an unrelated problem?
>
Oh, i did not notice this, it would probaly not be good - hopefully the
modem would be smart enough not to do this once it had already seen a RTC
on line, but then again maybe not. If the fax at the other end sees
multiple RTC's which are basically a series of end of line characters it is
very likely to think the page being sent is no good and ask for it to be
transmitted again - a retrain.
Have you got a 1496 manual, is there a S-Register to turn this 'feature' off?
- Robert