I have a USR 33.6 Faxmodem Sportster running in Class 1, with faxgetty(1)
for fax I/O, PPP I/O, and UUCP I/O. Changing config.cua1 from:
ModemRate: 38400
to:
ModemRate: 57600
makes the modem go away-it can't initialize, (can't deduce modem type.)
Is it possible to use this at 57600, or is this some kind of a violation?
Thanks,
John
BTW, the system is Linux, hardware flow control, config.cua1 is attached.
The system works reasonably well at 38400.
--
John Conover, 631 Lamont Ct., Campbell, CA., 95008, USA.
VOX 408.370.2688, FAX 408.379.9602
conover@inow.com, http://www2.inow.com/~conover/john.html
# $Id: usr-rts,v 1.6 1996/06/24 02:58:43 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
# Configuration for using the Class 1 command interface with
# a USR Courier or Sportster modem and RTS/CTS flow control.
#
CountryCode: 1
AreaCode: 408
FAXNumber: +1.408.379.9602
LongDistancePrefix: 1
InternationalPrefix: 011
DialStringRules: etc/dialrules
ServerTracing: 1
SessionTracing: 11
RecvFileMode: 0666
LogFileMode: 0666
DeviceMode: 0666
RingsBeforeAnswer: 1
SpeakerVolume: off
GettyArgs: "-h %l F38400 vt100"
LocalIdentifier: +14083799602
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "From %%l|%c|Page %%p of %%t"
PercentGoodLines: 50
MaxConsecutiveBadLines: 100
MaxRecvPages: 100
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class1 # use class 1 interface
ModemRate: 38400 # max rate for DCE-DTE communication
ModemFlowControl: rtscts # hardware flow control
#
ModemSetupDTRCmd: ATS13=1&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
ModemNoFlowCmd: AT&H0&I0&R1 # setup modem for no flow control
ModemHardFlowCmd: AT&H1&I0&R2 # setup modem for hardware flow control
ModemSoftFlowCmd: AT&H2&I2&R1 # setup modem for software flow control
ModemResultCodesCmd: ATQ0X4 # enable result codes
#
ModemMfrQueryCmd: !USR
ModemModelQueryCmd: ATI3
ModemRevQueryCmd: ATI7 # XXX, returns a multi-line result
#
# When AT+FCLASS=1 is issued the modem automatically switches
# to software flow control; these parameters let the fax software
# reset flow control as needed after entering Class 1.
#
Class1NFLOCmd: AT&H0&I0&R1 # setup modem for no flow control
Class1HFLOCmd: AT&H1&I0&R2 # setup modem for hardware flow control
Class1SFLOCmd: "" # modem does this automatically
#
# The remainder of this configuration is included so that the
# modem "idles" in Class 1 while not sending or receiving facsimile.
#
ModemSetupAACmd: AT+FAA=1+FCLASS=1&H1&I0&R2&A0&S1 # leave modem in class 1
ModemAnswerCmd: AT+FAA=1+FCLASS=1&H1&I0&R2&A0&S1A # force RTS/CTS after change to fax mode
ModemAnswerDataCmd: AT&F1S2=255S7=90S13=1S19=90&A0&D2&S1E1M0A # force reset after change to data mode
ModemWaitForConnect: yes # wait for CONNECT on answer