Hylafax Mailing List Archives

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: hylafax sendfax disconnecting after negotiation



Setting it up with Class1 also solved my problem.  But it broke the grand
functionality of autodetecting incoming data/fax calls.  So, now the question
is how do I make USR replace my modem with a class2.0 chipset that works?

Does USR even have a fully functional chipset?  Or atleast one that will
fix this bug that Hylafax finds?

-Josh

On Tue, Feb 03, 1998 at 10:20:12AM +0100, Maurice.Libes@com.univ-mrs.fr wrote:
> > 
> > > 
> > > Eric, I'm having a problem with HylaFax 4.0.. I'm using the Redhat RPM
> > > hylafax-4.0-6.i386.rpm version.  I saw your note about 'sendfax' problems
> 
> i got exactly the same problem 2 weeks ago....
> someone told me that it was due to the firmware of Class2.0 USR modem (i have a
> U.S. Robotics Sportster MessagePlus 56000 Rev. 11.1.18 )
> 
> i solve the problem (dont ask me why and how!) in configuring my modem in
> Class1 (i just got the config/usr-rts template file as etc/config.cua0
> configuration file,... and now emission/reception is OK although the
> documentation tells that hylafax will do the best with a 
> Class2 or Class2.0 modem)
> 
> SO ...i would want to know if there is a more elegant solution, in order to
> avoid Class1 parameters... is there a new release of a configuration file
> for USR Class2 or Class2.0 modems?
> 
> thanks for answers
> 
> 
> ML
> 
> 
> > 
> > The general advice is build from source; note that this is probably in
> > Redhat format, but not from Redhat.
> > 
> > > and exit with a "SEND FAILED: Unspecified Transmit Phase B error".
> > 
> > Most problems on the list have this generic symptom; more detail is
> > needed.
> > 
> > > I had sent in my USR Sporster modem in to get fixed.  USR replaced it
> > > with a new one.  While that was in the mail, I had upgraded HylaFAX versions.
> > 
> > The Sportster firmware from about 6 months ago had broken Class 2 support,
> > which would be obviously in a trace.  The workaround is to use Class 1.
> > 
> > 
> 
> 
> -- 
> ---
> 		    		   Maurice Libes
> 
> Telephone : +33 (04) 91 82 93 25   Fax : +33 (04) 91 82 93 03       
> Adresse Postale : Centre d'Oceanologie de Marseille FR6106 CNRS 
>                   Campus de Luminy , Case 901 F-13288 Marseille cedex 9
> mailto:libes@com.univ-mrs.fr
> URL: http://www.com.univ-mrs.fr/personnel/momo.html

-- 
Josh Hildebrand          Email: josh@digitalsluice.com
Digital Sluice           Pager: http://www.digitalsluice.com/josh/pager
Phone: 512-255-9797      Fax: 512-246-2861



Home
Report any problems to webmaster@hylafax.org

HylaFAX is a trademark of Silicon Graphics Corporation.
Internet connectivity for hylafax.org is provided by:
VirtuALL Private Host Services