Re: about the Sportster 33.6 Class 2 Bug



Hi !


Regarding errors in communication between USR Sportsters and plain faxes
(tested with Canon S 270 and some Panasonics) when faxsend start cycling
with mentioned errors:

> Aug 22 21:54:30.48: [  492]: --> [25:+FNF:=AD=1B+FCI:"(408) 379-96]
                                    ^^^^^^^
>     Aug 22 21:54:30.48: [  492]: REMOTE NSF "=AD=1B+FCI:"(408) 379-96"
>     Aug 22 21:54:30.48: [  492]: --> [40:2"=14+FIS:1,5,0,2,1,0,0,0=B3=
> =02e=B3=02e=B3=02e=B3=02]

I found out that if I put:

Class2NRCmd:            AT+FNR=1,1,1,0  # setup status reporting command

in config file for modem, thinks go away.

I don't have a clue why or what, I just tested this and now faxes are
going thru. I've looked in the log message from mgetty+sendfax process and
found out that there is AT+FNR=1,1,1,0 instead AT+FNR=1,1,1,1 like in
hylafax.

		lp
			gody

----------------------------------------------------------------------------
matjaz.godec@elgo.si    |     Ul. Josipa Priola 35    | Telecommunications
tel/fax:+ 386 62 214460 |  si 2ooo Maribor, Slovenija |    CALDERA-LINUX
http://www.elgo.si/	|   Slovenian network "SloN"  | Internet consultant