Hylafax Mailing List Archives
|
[Date Prev][Date Next][Thread Prev][Thread Next]
[Date Index]
[Thread Index]
Re: about the Sportster 33.6 Class 2 Bug
- To: flexfax@sgi.com
- Subject: flexfax: Re: about the Sportster 33.6 Class 2 Bug
- From: Matjaz Godec <gody@elgo.si>
- Date: Sat, 30 Aug 1997 17:37:01 +0200 (CEST)
Hi !
Regarding errors in communication between USR Sportsters and plain faxes
(tested with Canon S 270 and some Panasonics) when faxsend start cycling
with mentioned errors:
> Aug 22 21:54:30.48: [ 492]: --> [25:+FNF:=AD=1B+FCI:"(408) 379-96]
^^^^^^^
> Aug 22 21:54:30.48: [ 492]: REMOTE NSF "=AD=1B+FCI:"(408) 379-96"
> Aug 22 21:54:30.48: [ 492]: --> [40:2"=14+FIS:1,5,0,2,1,0,0,0=B3=
> =02e=B3=02e=B3=02e=B3=02]
I found out that if I put:
Class2NRCmd: AT+FNR=1,1,1,0 # setup status reporting command
in config file for modem, thinks go away.
I don't have a clue why or what, I just tested this and now faxes are
going thru. I've looked in the log message from mgetty+sendfax process and
found out that there is AT+FNR=1,1,1,0 instead AT+FNR=1,1,1,1 like in
hylafax.
lp
gody
----------------------------------------------------------------------------
matjaz.godec@elgo.si | Ul. Josipa Priola 35 | Telecommunications
tel/fax:+ 386 62 214460 | si 2ooo Maribor, Slovenija | CALDERA-LINUX